50Hz 60Hz Global Warranty Open Silent 9 to 2250kva Perkins Diesel Generator with Stamford Alternator
Generator Model ................................Perkins generator series
Type of generator...............................Open type or silent type
Frequency/Speed................................50Hz/1500rpm, 60Hz/1800rpm
Voltage..............................................110/220,220/380,230/400
240/415, 254/440V
Rated Power.......................................9Kva-2250Kva
Standby Power...................................10Kva-2500Kva
Phase................................................3 Phase or 1 Phase
Fuel Tank Capacity..............................base fuel tank
Sound Level.......................................63dB to 95dB at 7 meter
Alternator..........................................Meccalte, Stamford, Leroy Somer,
Model | Standby | Prime | Perkins Engine | Stamford Alternator | Controller |
KVA | KVA | ComAp | |||
P9 | 10 | 9 | 403A-11G1 | PI 044E | AMF20 |
P15 | 16.5 | 15 | 403A-15G2 | PI 044G | AMF20 |
P20 | 22 | 20 | 404A-22G1 | PI 144D | AMF20 |
P300 | 33 | 30 | 1103A-33G | PI 144G | AMF20 |
P45 | 50 | 45 | 1103A-33TG1 | UCI 224D | AMF20 |
P60 | 66 | 60 | 1103A-33TG2 | UCI 224E | AMF20 |
P80 | 88 | 80 | 1104A-44TG2 | UCI 224G | AMF20 |
P100 | 110 | 100 | 1104C-44TAG2 | UCI 274C | AMF20 |
P150 | 165 | 150 | 1106A-70TAG2 | UCI 274F | AMF20 |
P180 | 200 | 180 | 1106A-70TAG3 | UCI 274G | AMF20 |
P250 | 220 | 200 | 1106A-70TAG4 | UCI 274H | AMF20 |
P225 | 250 | 225 | 1506A-E88TAG2 | UCDI 274J | AMF20 |
P250 | 275 | 250 | 1506A-E88TAG3 | UCDI 274K | AMF20 |
P275 | 300 | 275 | 1506A-E88TAG4 | HCI 444D | AMF20 |
P300 | 330 | 300 | 1506A-E88TAG5 | HCI 444D | AMF20 |
P350 | 385 | 350 | 2206C-E13TAG2 | HCI 444E | AMF20 |
P400 | 440 | 400 | 2206C-E13TAG3 | HCI 444F | AMF20 |
P450 | 500 | 450 | 2506C-E15TAG1 | HCI 544C | AMF20 |
P500 | 550 | 500 | 2506C-E15TAG2 | HCI 544C | AMF20 |
P550 | 600 | 550 | 2806C-E18TAG1A | HCI 544D | AMF20 |
P600 | 660 | 600 | 2806C-E18TAG1A | HCI 544E | AMF20 |
P650 | 720 | 650 | 2806A-E18TAG2 | HCI 544F | AMF20 |
P750 | 825 | 750 | 4006-23TAG2A | LVI 634B | AMF20 |
P800 | 880 | 800 | 4006-23TAG3A | LVI 634C | AMF25 |
P1000 | 1100 | 1000 | 4008TAG2A | LVI 634E | AMF25 |
P1250 | 1375 | 1250 | 4012-46TWG2A | LVI 634G | AMF25 |
P1350 | 1485 | 1350 | 4012-46TWG3A | PI734B | AMF25 |
P1500 | 1650 | 1500 | 4012-46TAG2A | PI734C | AMF25 |
P1650 | 1815 | 1650 | 4012-46TAG3A | PI734D | AMF25 |
P1850 | 2035 | 1850 | 4016TAG1A | PI734E | AMF25 |
P2000 | 2200 | 2000 | 4016TAG2A | PI734F | AMF25 |
P2250 | 2475 | 2250 | 4016-61TRG3 | PI734G | AMF25 |
P1375 | 1375 | 1250 | 4012-46TWG2A | LVI 634G | AMF25 |
Products list:
FAQ |
Q : Do you offer OEM service?
A : Yes
Q : What is the difference between Prime power and Standby power?
A : Prime power is 12hours continous power,one hour 10% over load in every 12 running hours is allowed .
Standby power is the limit value of maximum output for emergency use . Overloading is prohibited
Q : What about the warranty
A : Guarantee for one year or 1000 hours (accord to whichever reach first) from ex-factory date .During the
guarantee period ,our company will provide the free easy damaged spare part for problems caused by our
quality of production or raw material except the damageable spare parts of diesel engine caused by
customer's incorrect man made operation . After expiration , our company provides cost parts maintenance
for gen-set.