Military Product Fuel Saving 200KW 250KVA Huachai Deutz Open heavy duty diesel generator
DEUTZ is one of the world’s leading manufacturers of innovative drive systems. Its core competences are
the development, production, distribution and servicing of diesel, gas and electric drivetrains for
professional applications. The engine specialist offers a broad product spectrum with capacities ranging
up to 620 kW that is used in construction equipment, agricultural machinery, material handling equipment,
stationary equipment, commercial vehicles, rail vehicles and other applications.
PRODUCT DESCRIPTION |
Genset Model | BS-D250 | ||
Prime Power (kw/kva) | 200 / 250 | Standby Power(kw/kva) | 220 / 275 |
Voltage (v) | 400 | Rated Speed (rpm) | 1500 |
Frequency (Hz) | 50 | Rated Current (A) | 360.8 |
Connection: | 3 phase | Power Factor: | 0.8 |
Engine Model: | BF6M1015-LA G1A | Alternator Model: | UCDI274K |
Net Weight (kgs)-Silent | 2800 | Dimensions (mm)-Silent | 3450x1100x2070 |
Engine Parameter: | |
Manufacturer/Model Engine type
Control System Displacement Bore x Stroke Compression Ratio Power Effective pressure MAX. exhaust gas temperature Inlet air (25 /1000mbar) Fuel Consumption Max. noise value at 1m Battery voltage(V) Starter rated power (KW) Generator voltage(V) Max. exhaust back pressure (mbar) Max. allowable air inlet resistance (mbar) Lowest ambient temperature of cold starting without assistant Lowest ambient temperature of cold starting with flame preheat plug | DEUTZ BF6M1015-LA G1A CAC Inter-cooling mechanical /electronic 11.906 L 132 x 145 mm 16.5 : 1 250 KW 16.8 bar 463℃ 1124 m3/h 196g/kw·h ≤94 dBA 24 9 28.5 50 50
-17℃
-32℃ |
Fuel System | |
Cylinder ignition sequence Idle speed (rpm) Low-pressure pump oil load capacity (L/h) Fuel filter element type No. of the fuel filter element | 1-6-3-5-2-4 600±50 190 Disposable filter 2 |
Lube System | |
Oil Consumption (as % of fuel consumption) oil temperature 90℃ Min. oil pressure at 1500rpm Min. oil pressure at 600rpm Oil temperature of normal operation Initial oil filling Oil filter element type No. of oil filter element | <0.3% of fuel consumption
≥3 bar ≥1 bar <130 ℃ 38 L Disposable filter 1 |
Cooling system | |
Engine coolant capacity( L) Water-pump flow (L/min) Water-pump pressure (bar) Allowable pressure loss of cooling system (include pipeline) (bar) Heat carry off by coolant (kW) In&Outlet coolant size (mm) Temperature of switch on two thermostats respectively (℃) Temperature of switch on two thermostats totally (℃) Max. allowable operating temperature (℃) Temperature difference between inlet and outlet coolant (℃) Inter-cooler cooling power(KW) Fan Fan connection Fan diameter (mm) Air volume of fan(m3/s) Fan power consumption (kW) Fan transmission ratio | 17 260 1.25
≤0.35 138 70
79/87
94/102 103
≤8 52 Exhaust type Gear drive + coupler 880 4.6 ≤14 0.96 |
Alternator Parameter: Basic Information | |
The alternators meet the standards of: GB755, BS5000, VDE00530, NEMAMG1-22,IED34-1,CSA22.2 and AS1350 | |
Technical Data | |
Manufacturer Phases Bearing numbers Power Factor Protection Class Altitude Condition Excitation Insulation class/Temp. rise class Tel. Influence Factor TIF Tel. Harmonic Factor THF Steady State Voltage Regulation Alternator Capacity Efficiency | STAMFORD UCDI274K 3 1 0.8 IP23 ≤1000M Brushless, self-excitation H / H <50 <2% ≤±1% 200KW 92.7% |
Standard configuration of diesel generator set for open type :
1 . all kinds of engine brand as options for customer
2 . Stamford alternator ( Copy stamford or other brand for option )
3 . SMARTGENT or Deepsea control panel
4 . circuit breaker
5 . 8 Working Hours Base Fuel Tank , many kinds of base frame for options .
6 . Anti-Vibration Mounted System
7 .Battery and battery charger
8 . Industrial silencer and flexible exhaust hose
FAQ |
Q : What is the difference between Prime power and Standby power ?
A : Prime power is 12hours continous power , one hour 10% over load in every 12 running hours is allowed .
Standby power is the limit value of maximum output for emergency use . Overloading is prohibited
Q : How to choose the power ?
A : Collect all power of your equipments , take the current into your consideration .
Q : Does your generator have global warranty?
A : Yes . Global warranty service is available depending on the engines and alternators you choose .
Q:What is your MOQ?
A: Above 1pc
Q: Do you offer OEM service?
A: Yes
Q: What is your lead time?
A: About 30 days after receiving deposit or original L/C.But if your order with some special design,
then the delivery time is longer.
Q: What is your payment term?
A: 30% T/T in advance, the rest payment before shipment. Or irrevocable L/C.