Perkins Diesel Generator Reliable power 4006-23TAG3A Economic Power 800kva
AI power generation system, providing optimum performance, reliability, and versatility for stationery standby, prime power, and continuous duty applications. All generator sets are prototype tested, factory build, and production tested.
High quality, reliable and complete power unit
Compact design
Easy start and maintenance possibility
Every generating set is subject to a comprehensive test program which includes full load testing, checking and provision of control and safety shut down functions testing
Fully engineered with a wide range of options and accessories : Canopy, sound proof canopy and on-road trailer
Open Type | ||
---|---|---|
Dimensions (LxWxH) | mm | 4050 x 2000 x 2201 |
Dry Weight | kg | 5400 |
Sound Attenuated Type | ||
Dimensions (LxWxH) | mm | 5806 x 2267 x 2554 |
Dry Weight | kg | 7550 |
Voltage | Standby Rating (ESP) | Prime Rating (PRP) | ||
---|---|---|---|---|
kVA | kW | kVA | kW | |
400/230 | 900 | 720 | 810 | 648 |
Manufacturer | Perkins | ||
---|---|---|---|
Model | 4006-23TAG3A | ||
Engine Power Output at rated rpm | kWm | 786 | |
HP | 1053.6 | ||
No. of Cylinders and Build | 6 In Line | ||
Engine Speed | rpm | 1500 | |
Aspiration and Cooling | Turbocharged | ||
Total Displacement | L | 22.921 | |
Bore and Stroke | mm x mm | 160x190 | |
Compression Ratio | 13.6:1 | ||
Governor | Electronic | ||
Fuel Consumption at full load | L/hr | 172 | |
Fuel Tank Capacity | Litre | Open : 1100 / Canopy : 1450 / Container : 1000 | |
Oil Capacity | Litre | 113.4 | |
Coolant Capacity | L | 105 | |
Radiator Cooling Air | m³ /min. | 1200 | |
Air Intake - Engine | m³ /min. | 73 | |
Exhaust Gas Flow | m³ /min. | 193 |
Design | Brushless single bearing, revolving field/td> | |
---|---|---|
Stator | 2/3 pitch | |
Rotor | Single bearing, flexible disc | |
Insulation System | Class H | |
Standard Temperature Rise | 125 - 163°C Continuous | |
Exciter type | Self Excited | |
Phase Rotation | A (U), B (V), C (W) | |
Alternator Cooling | Direct drive centrifugal blower fan | |
AC Waveform Total Harmonic Distortion | No load <1.5% Non distorting balanced linear load < 5% | |
Telephone Influence Factor (TUF) | <50 per NEMA MG-1-22.43 | |
Telephone Harmonic Factor (THF) | <2% |
EASY TO MAINTAIN
The daily maintenance work can be performed on both sides of the machine, and wide door allows you easily get in touch with the machine.
An integral base drainage outlet located at the bottom of the machine makes easier regular maintenance.
For generators above 300Kva, a ladder for climbing is equipped. It makes easier to check and service.