NC feeder, pipe stamping processing, Ruihui punch feeding equipment
The NC feeder is the most convenient three-feeder type with the most convenient installation, the most convenient use, the simplest operation, the highest feeding accuracy, the most stable performance, the lowest failure rate and the simplest maintenance.
Reasons why the NC feeder is not feeding properly:
1. The external air supply pressure of the NC feeder is insufficient, which causes the clamping and loosening cylinders to not operate normally;
Ruihui NC feeder uses cylinder clamping and relaxation. If the pressure of the air source is insufficient, the cylinder will not operate normally, which will affect the normal feeding action. At this time, the three-point combination of the NC feeder can be checked to see the pressure gauge. Pressure, check the external air source to solve.
2. The pressing force of the material feeding spring of the NC feeder is not enough; the pressure of the feeding spring of the feeding machine is not adjusted well, which will cause the material to slide between the rollers, which will result in inaccurate feeding. At this time, the pressing force of the pressing spring is appropriately increased. Just fine.
3. The feeding or loosening time of the NC feeder is not correct; the stamping process of different molds is different, and the actual feeding time and relaxation time are different.
When many customers actually use Ruihui NC feeder, they often adjust the feeding height after changing the mold, but do not change the feeding and relaxation time, causing feeding and relaxing too early or too late, which causes the feeding to be inaccurate. When re-adjusting the feeding and relaxation time of the NC feeder.
4. The actual feeding speed of the NC feeder is too fast; the NC feeder is not a high-speed feeding device due to the limitation of the response time of the electric control system. The punching speed is generally more than 200 times, and the NC feeder can't keep up. Only other high-speed feeding devices can be replaced at this time.
5. There is oil or foreign matter in the feeding roller of the NC feeder. There is a material in the NC feeder drum that can cause the material to slip and the material cannot be clamped; if there is foreign matter in the drum, the gap will be inaccurate, and the drum can be cleaned at this time.
Specification:
Model | MAC2-400 | MAC2-500 | MAC2-600 | MAC2-800 | ||
Stock Width(mm) | 50-400 | 50-500 | 50-600 | 50-800 | ||
Stock Thickness(mm) | 0.3~3.2 | 0.3-3.2 | 0.3-3.2 | -3.2 | ||
Max.Coil Weight(kg) | 3000 | 3000 | 3000 | 5000 | 5000 | 7000 |
Max.Coil O.D.(mm) | 1200 | 1200 | 1200 | |||
Coil I.D.(mm) | 8 | 8 | 508 | 508 | ||
Feed Length(mm) | ~500* | ~500* | ~500* | ~500* | ||
Max. Line Speed(m/min) | 16-24 | 16-24 | 16-24 | 16-24 | ||
Work Roll Number(pieces) | upper 6 lower 5 | upper 6 lower 5 | upper 6 lower 5 | upper 6 lower 5 | ||
Feed Roll Number(set) | 1 | 1 | 1 | 1 | ||
Main Motor(kw) | AC2.9 | AC2.9 | AC4.4 | AC4.4 | ||
Mandrel Expansion | hydraulic | hydraulic | hydraulic | hydraulic | ||
Reel Motor(kw) | 1.5 | 1.5 | 1.5 | 2.2 | 2.2 | 3.7 |
Power(V) | 3 Phase 220V/380V/50HZ | |||||
Operating Air(Mpa) | 0.49 | 0.49 | 0.49 | 0.49 |
Straigtening performance:
tock Thicknees (mm) | Stock Width (mm) | |||
0.3 | 400 | 500 | 600 | 800 |
0.4 | ||||
0.6 | ||||
0.8 | ||||
1.0 | ||||
1.2 | ||||
1.4 | ||||
1.6 | 470 | 470 | ||
1.8 | 400 | 400 | ||
2.0 | 360 | 360 | ||
2.3 | 300 | 300 | 300 | 300 |
2.5 | 230 | 230 | 230 | 230 |
2.8 | 150 | 150 | 150 | 150 |
3.2 | 110 | 110 | 110 | 110 |
*1:(Pneumatic):Option in case of pneumatic mandrel expansion is provi