LK-A35 Electric Portable Dental Clinic Chair Suppliers with Air Compressor, light cure and Ultrasonic Scaler
The dental chair supplies configuration:
1- aluminium alloy suction handle
2- 3-way syringe(water,air,atomization)
3- pressure gage for air tank
4- high speed handpiece inlet
5- low speed handpiece inlet
6- water adjustor
7- air adjustor
8- atomization adjustor
9- air adjustor
10- valve of clean water bottle
11- dirt-collecting bottle 600ML
12- clean water bottle 600ML
13- foot pedal
The dental chair supplies Technical Specification:
Input power | 110V/220V, AC: 60HZ/50HZ |
Current | 2.4A |
Motor power | 600W |
Nominal volume | 65L/min |
Starting pressure | 0.5Mpa±0.05Mpa |
Rated exhausting pressure | 0.8Mpa±0.05Mpa |
N.W. | 26kg |
G.W. | 30kg |
Product size | 44*34*63cm |
Packing size | 51*40*69cm (Honeycomb carton) |
The dental chair supplies Standard accessory:
Oilfree air motor: 1 set
Built-in air tank(8L): 1 set
2 hole/4 hole handpiece tube: 2 sets
3-way syringe: 1 set
600ML clean water bottle: 1 set
600ML waste water bottle: 1 set
Round foot pedal: 1 set
Electric weak suction: 1 set
Built-in ultrasonic scaler: 1 set
The dental chair supplies with the compressor that can work directly not requested any gas storage tank. With a stable source of clean air, there is no trouble of sewage drainage as of a traditional compressor with tank. It is easy to operate. Also it can supply with a sustainable pressure for high-speed handpiece, low-speed handpiece, and other installations as dental descaler, light curing, etc. But it weights only 30KGs. It’s convenient to be carried with. It would be the first choice for dentist who needs to give emergent service.
The dental chair supplies Warranty
Warranty, One year period of validity.
In the cases below are not under warranty:
Damage caused by human error.
Damage caused by impropriate operation.
Damage caused by against the instruction operate requirement.
The dental chair supplies Attention:
Attention to the pressure adjusting valve on the machine control panel, the pressure is 0.5~0.6 MPA already set by the manufacture. Do not mobilize this valve at your will, or this unit can’t work normally when pressure is too high, and you would damage the handpiece tubes or other components.
After use, cut off the power, and once again step on the foot control pedal to release all residual gas in the machine motor and other tubes. Make sure that the pressure on handpiece and the pressure on compressor get to zero. If not, the machine will be damaged as a result of long-term pressure of residual gas.