Specifications
Brand Name :
S&D
Model Number :
#16/02
Certification :
TUV CE, ISO13485, ISO9001
Place of Origin :
P. R. China
MOQ :
100 Packs
Price :
Negotiable
Payment Terms :
T/T, Western Union, MoneyGram, L/C, D/P, D/A
Supply Ability :
500 packs per day
Delivery Time :
3~25 days
Packaging Details :
10packs/box, 180boxes/carton
Material :
Nickel Titanium
Size :
#16/02
Length :
21mm, 25mm, 31mm
Surface color :
Gold
Instrument classification :
Class 2
Package :
6pcs/pack
Description

Dental Process With Heat-Treatment Gold Color Rotary Endo Files P Glider File Is Flexible For Searching Root Canal

S&D P Glider file

This is the dental file used s used in endodontic treatment to expand the glide path in preparation for mechanized NiTi files.

These instruments are to be used only by licensed clinicians.

2.Main materials

1) Cutting Nickel Titanium(including nickel and chromium)

2) Shank: copper

Purpose of use and effect -efficacy

only be used in should be used in clockwise rotary motion only with original settings,

Specifications

Under the provisions of ISO 13485 performance test, product durability for twisting and bending must exceed specified value of our standard.

#16 02

Method of manipulating or method of use

at a speed of 300 rpm with light apical pressure, and set at 2-5.2 Ncm for torque control. 250 – 300 rpm

Precautions for use

1.To prevent infection, sterilize the product by autoclave and make sure sterilization is completed before using .

2. Choose the most appropriative type for each case and follow the general method.

3.Before using, make sure the instruments outside of oral cavity that there are no deformations, scratches and cracks .

4. If the head of product is thin, long or large, there are possibilities for breaking or twisting. Because of this, be sure to avoid using unreasonable angle and excessive pressure.

5.Wear safety glasses to protect your eyes from damage. Also, wear a dust protective mask to prevent inhaling dust .

6.A chain, string, or other instrument shall be attached to the hole through the shank to prevent it from falling into the mouth.

7. A rubber dam or gauze screen should be used to prevent accidental ingestion and aspiration. Patients with a high likelihood of accidental ingestion or aspiration should not be treated in a horizontal position and should be treated in a seated position whenever possible.

8. Do not use this instrument for any purposes except for listed applications above.

9.Only for use by dentists.

10.This product should be treated as medical waste when disposed.

11.Dispose the product if damaged or contaminated .

12.After using, wash it with medical cleaning agent and brush, then wash away foreign substances like adherent body fluids and body tissues.

13.Avoid using unreasonable angle and excessive pressure.

14. This product has possibility that be corrosive if sunk into NaOCl, EDTA and etc . for a long time.

Storages and duration of use

1. Avoid storing at high temperature, humidity and direct sunlight.

Keep liquids away. Store it at room temperature.

2. Do not damage or make a pinhole to packaging materials.

3. The product is subject to be improved without previous notice. Enforce

the first-in first-out method for stock management.

4. Do not store the product under a germicidal lamp to avoid deterioration.

Maintenances and inspections

Sterilize this product by autoclave under established method and term for each use.

Method of sterilization:

Put this product in a sterilization pack (or foil) and place it on a sterilization tray, or files stand for autoclave sterilization with reference to the following terms.

Terms for sterilization:

term(1) temperature: 134degrees Celsius time: 15 minutes or more

2.Do not use high pressure steam sterilizer which heats more than 200 degrees Celsius including drying process .

Instruction of using

Before using a P-Glider file, explore the canal up to a .010 K-file.

to follow the canal until working length is achieved.

Dental Heat Treatment Rotary Endo Files Systems P Glider File Instrument For Root Canal Treatment

Send your message to this supplier
Send Now

Dental Heat Treatment Rotary Endo Files Systems P Glider File Instrument For Root Canal Treatment

Ask Latest Price
Brand Name :
S&D
Model Number :
#16/02
Certification :
TUV CE, ISO13485, ISO9001
Place of Origin :
P. R. China
MOQ :
100 Packs
Price :
Negotiable
Contact Supplier
Dental Heat Treatment Rotary Endo Files Systems P Glider File Instrument For Root Canal Treatment

Shanghai S&D International Dental Co., Ltd.

Verified Supplier
3 Years
Since 2004
Business Type :
Manufacturer, Agent, Exporter, Trading Company
Total Annual :
5000000-10000000
Employee Number :
50~200
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement