Stainless Steel Endodontic Reamer product description:
Section | ||||
Length | L21 | L25 | L28 | L31 |
Size | #6/#8/#10/#15/#20/#25/#30/#35/#40/#45/#50/#55/#60/#70/#80 | |||
Sterilization | ≤126°C | |||
Cross Section | For size ![]() |
Stainless Steel Endodontic Reamer Detailed Product Description
Product Name: | Hand Use Stainless Steel Reamers | Size: | 15-40,45-80 |
---|---|---|---|
Taper: | .02 | Standard: | CE/ISO/FDA/FSC |
Application: | Used For Expand Root Canal | Length: | L21/25/28/31mm |
Packing: | 6 Pieces/ Pack With Difference Color From #15-40 | Color: | White , Yellow , Red , Blue , Green , Black |
Specifications:
reaming motion in endodontics
Brand | D-Perfect |
Model Size | #15-40 , #45-80 |
Tper | .02 |
Lenth | L21/25/28/31mm |
Usage | Good instruments used for expand and smooth canal |
Advantage | Best instruments for smooth the canal |
reaming motion in endodontics Description:
1. Import dental class raw materials from Korea
2. Silicone pad fixed length when root canal treatment
3. Each file has a corresponding ISO international common model
4 cross-section of the circular design, cutting ability test
5. With excellent cross section design , can make root canal wall more smooth
6. Handle has a clear cross-sectional shape and type of logo
7. Silicone pad handle can be applied to 130 ℃ high temperature sterilization
8. Different types of packaging to meet the needs of different doctors
Operation Sequence:
reaming motion in endodontics
1. Preparation of the root canal wall.
2. Open the pulp.
3. Search and locate the root canal.
Reamer files Warning:
1. Only dentists can use
2. Before use, make sure to disinfect.
3. According to the intended use.
Detailed Product Description
Product Name: | Hand Stainless Steel H Files | Size: | #15-40 |
---|---|---|---|
Taper: | .02 | Standard: | CE/ISO/FDA/FSC |
Application: | Cutting Instruments For Fast Remove Root Canal Debris | Length: | L21/25/28/31mm |
Material: | Stainless Steel 304 | Color: | White , Yellow , Red , Blue , Green , Black |
Root canal H Files Assorted size Manual use Stainless Steel instruments used for dental
Description:
1. Stainless steel raw materials imported from South Korea, quality assurance
2. ISO corresponding to the international standard model with the color
3 silicone pad on the handle, root canal treatment can be more fixed length
4. The handle also has a cross-sectional shape of the file logo, clearly distinguish the model
5. Stainless steel needle shape more gentle and stable
6. Have a circular cross-section to remove necrotic pulp more thoroughly
7. ISO 15-40, 45-80 size, providing accurate dentistry to all dentists
8. Special steel alloy structure, the maximum anti-fracture and maximum flexibility
9. Suitable for different sizes of tubes, a box will be able to meet the needs of doctors for different root canal, lower cost
10. Can be different packaging design, can ODM, also accept OEM
11. Can also be sterile packaging
Specification
Brand name | D-Perfect |
Model size | 15-40 |
Tper | .02 |
Lenth | L21/25/28/31mm |
Application | Cutting instruments for fast remove root canal debris |
Advantage | Stronger cutting force |
Operation Sequence:
1. General opening tooth crown.
2. Search and locate the root canal.
3. Use fast cutting instruments
4. Use H files to remove the debris.
Precautions for use:
1. Please use autoclave to sterilization before use to prevent infection
2. Make sure the needle is not cracked before use, do not over-use
3. According to different root canal choose different models to improve worker safety
4. Please pay attention to the silicone stopper, to avoid falling into the patient's mouth during use
5. Only used for root canal treatment
6. Wear rubber dam, avoid accidental swallow and fall.
7. Do not use this reamer dental instrument for any purpose other than the applications listed above.
8. Only for dentists.
9. After use, dispose of as medical waste properly.
10. Dispose of if product is damaged or contaminated.
11. After use, wash it with a medical detergent and a brush, and then wash away any foreign material such as bodily fluids and body tissues.
12. When using the ultrasonic cleaning machine, please place the product on the bracket, in order to avoid deterioration of working parts.
13. Use this product with great care to avoid puncturing your fingers because the fingers have sharp parts.
Storages and duration of use
1. Avoid being stored in a hot, humid and direct sunlight environment.
2 recommended 5 root canal, do not over-use.
Maintenances and inspections:
1. Terms for sterilization:
term(1) temperature: 121degrees Celsius time: 20 minutes or more
term(2) temperature: 126degrees Celsius time: 15 minutes or more
2. Do not use high pressure steam sterilizer which heats more than 200
degrees Celsius including drying process.
3. When reusing the instrument, wash away foreign substances
completely and sterilize.
4. Regarding use of medical cleaning agent, follow the instruction
manual by its manufacturer strictly.
5. Dispose the product if damaged or decreased in performance
Packages
Minimum packaging unit: 6 pcs. /package ( 15-40 )
Competitive Advantage:
Strong and stable instruments for searching root canal ,shaping and cleaning canal walls.
Enhanced safety – infection control made simple
TÜV-certified Quality Management
Precautions for use:
1. To prevent infection, sterilize the product with an autoclave and ensure sterilization is completed before use.
2. Choose the most appropriate type for each situation and follow the general approach.
3. Before use, make sure that there is no deformation, scratches and cracks in the instrument outside the dental cavity.
4. If the product's head is thin, long or large, it may break or twist. Therefore, we must avoid using unreasonable angles and excessive pressure.
5. Wear safety glasses to protect your eyes from injury. In addition, wear protective masks to prevent inhalation of dust.
6. Wear rubber dam, so as to avoid accidental swallow and fall.
7. Do not use this instrument for any purpose other than the applications listed above.
8. Only for dentists.
9. After use, dispose of as medical waste properly.
10. Dispose of if product is damaged or contaminated.
11. After use, wash it with a medical detergent and a brush, and then wash away any foreign material such as bodily fluids and body tissues.
12. When using the ultrasonic cleaning machine, please place the product on the bracket, in order to avoid deterioration of working parts.
13. Use this product with great care to avoid puncturing your fingers because the fingers have sharp parts.
Storages and duration of use:
1. Avoid high temperature, humidity and direct sunlight stored.
Keep liquid. Store it at room temperature.
2. Do not damage the packaging materials, do not do pinhole.
3. Do not put under the germicidal lamp, in order to avoid deterioration.
Stainless Steel Endodontic Reamer Maintenances and inspections:
1. Sterilize the product by autoclaving according to established methods and terms.
Sterilization method:
Place the product in a sterilization pack or foil, place it on a sterilizing tray, or refer to the following terminology file for sterilization.
Sterilization Terms:
(1) Temperature: 121 ℃ Celsius time: more than 20 minutes
(2) Temperature: 126 degrees Celsius Time: 15 minutes or more
2. Do not use autoclaves heated to over 200 degrees Celsius, including the drying process.
3. When reusing the instrument, completely remove foreign material and sterilize it.
4. On the use of medical cleaning agents, in strict accordance with the manufacturer's instructions.
5. If the product is damaged or degraded, discard the product
Packages
1. Minimum packaging unit: 6 pcs. /package (#15-40, #45-80)
OEM is available
Applications:
Dental Root Canal Treatment | Hospital , Clinic , lab... |
Stainless Steel Endodontic Reamer Competitive Advantage:
Strong and stable instruments for searching root canal ,smooth the canal walls.
Enhanced safety – infection control made simple
TÜV-certified Quality Management