Specifications
Brand Name :
GET
type :
diesel water pump
suction/discharger port diameter mm(inch) :
50(2'). 80(3'). 100(4'). 150(6')
discharge capacity(m³/h) :
30 40 110 150
total head lift :
25m 26m 22m 20m
self-priming time (s/4m) :
80 120 180 180
max suction head :
8m 8m 8m 6m
rotation speed (r/min) :
3600
noise level db(A)/7m) :
85
overall dimension(mm) :
510x455x640. 560x455x655. 650x470x700. 770x574x785
dry weight :
44kg 50kg 71kg 95kg
engine model :
GET173F GET178F GET186FA GET192F
rated power :
2.8kw 4kw 6.3kw 8.5kw
fuel consumption g/kw.h :
288 285 281 281
displacement (cm³) :
247 296 418 498
starter system :
recoil starter
fuel tank capacity :
13.5L
continuous working period :
10hr 10hr 8hr 8hr
Place of Origin :
China
Certification :
ISO CE
Price :
Negotiable
Delivery Time :
15-20 workdays
Payment Terms :
LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram
Description

High Pressure Diesel Engine Pumps Diesel Fire Fighting Pump

Here is a description of the key features and components of a Diesel Fire Fighting Pump:

  1. Diesel Engine: A diesel fire pump is equipped with a diesel engine as its power source. Diesel engines are known for their reliability, durability, and ability to provide consistent power even in demanding conditions. The engine drives the pump system to deliver the required water flow and pressure.

  2. Pump Assembly: The pump assembly consists of the impeller, casing, and other components responsible for water intake, impeller rotation, and water discharge. The impeller creates centrifugal force, which pushes the water outward, generating the necessary pressure for firefighting.

  3. Controller and Monitoring System: A diesel fire pump is typically equipped with a control panel and monitoring system. The controller allows for automatic or manual operation of the pump, including starting, stopping, and controlling the speed. The monitoring system provides real-time information on pump performance, including pressure, temperature, and alarms for any malfunctions or abnormalities.

  4. Fuel System: The fuel system supplies diesel fuel to the engine for combustion. It includes components such as fuel tanks, fuel filters, fuel pumps, and fuel lines. The fuel system ensures a reliable and continuous supply of fuel to the engine during operation.

  5. Cooling System: The diesel engine requires a cooling system to maintain the optimal operating temperature. The cooling system typically consists of a radiator, coolant fluid, fan, and circulation pump. It dissipates the heat generated during engine operation, preventing overheating and ensuring efficient performance.

  6. Exhaust System: The exhaust system is responsible for safely removing the combustion gases from the diesel engine. It includes components such as the exhaust manifold, muffler, and exhaust pipes. The exhaust system may also incorporate noise reduction features to minimize the noise emissions during operation.

  7. Electrical System: The electrical system of a diesel fire pump includes a battery for starting the engine and powering the control panel and monitoring system. It may also have an alternator to recharge the battery while the engine is running.

  8. Enclosure and Protection: Diesel fire pumps are typically housed in a protective enclosure or pump room to provide weather protection and prevent unauthorized access. The enclosure may also have soundproofing features to reduce noise levels during operation.

  9. Fire Pump Controller: A fire pump controller is a vital component of a diesel fire pump system. It monitors the water pressure in the fire protection system and automatically starts the pump when the pressure drops below a certain level. The controller ensures a quick response to fire emergencies and maintains adequate water supply for firefighting operations.

  10. Compliance with Standards: Diesel fire pumps are designed and manufactured in accordance with specific industry standards and regulations, such as NFPA 20 (National Fire Protection Association). These standards ensure that the fire pumps meet the necessary safety, reliability, and performance requirements for fire protection systems.

Model JBC6/10
Type vacuum pump
Max.Flow(T/h) 48
MAX.Lift(m) 60
Rated Speed(rpm) 3600
Water Shot Height 35m
Engine 190F
Maximum Suction Height(m) 7
Self-priming Time(S) 20
Discharge Port Diameter(mm) 65
N.W/G.W(KG) 91/100
Dimensions(mm)
Loading Qty(20GP/40HQ)
Model JBC6/15
Type vacuum pump
Max.Flow(T/h) 54
MAX.Lift(m) 80
Rated Speed(rpm) 3600
Water Shot Height 35
Engine 192
Maximum Suction Height(m) 7
Self-priming Time(S) 20
Discharge Port Diameter(mm) 65
N.W/G.W(KG) 94/103
Dimensions(mm)
Loading Qty(20GP/40HQ)

Diesel Fire Fighting Pump are crucial for providing a reliable water supply in fire protection systems, helping to suppress and control fires effectively. Their robust diesel engines, pump assemblies, monitoring systems, and safety features make them essential components of fire safety infrastructure in various buildings and facilities.

4KW 6.3KW Diesel Engine Pumps 13.5L Diesel Powered Water Pump

Send your message to this supplier
Send Now

4KW 6.3KW Diesel Engine Pumps 13.5L Diesel Powered Water Pump

Ask Latest Price
Brand Name :
GET
type :
diesel water pump
suction/discharger port diameter mm(inch) :
50(2'). 80(3'). 100(4'). 150(6')
discharge capacity(m³/h) :
30 40 110 150
total head lift :
25m 26m 22m 20m
self-priming time (s/4m) :
80 120 180 180
Contact Supplier
4KW 6.3KW Diesel Engine Pumps 13.5L Diesel Powered Water Pump

Wuxi Guangertai Power Machinery Co.,Ltd

Verified Supplier
2 Years
Business Type :
Manufacturer, Exporter, Seller
Employee Number :
>100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement