Wiring capacity
Detachable screw terminal, 0.2... 2.5mm ² Hard or soft
Detachable screw terminal, 0.25... 2.5mm ² flexible single conductor with wire hoop
Detachable screw terminal, 0.2... 1.5mm ² Hard or soft double wire
Detachable screw Terminal, 2 x 0.25... 1 mm² Flexible wire with wire hoop without cable end, with bezel
Detachable screw terminal, 2 x 0.5... 1.5mm ² Flexible wire with wire hoop with cable end, with frame
Rated supply voltage [Us]
24 V AC - 15... 10%
24 V DC-20... 20%
Supplementary information
Synchronize time between two inputs
0.5s
2 s
4 s
Startup type
Automatic/manual/monitored
Power consumption [W]
2.0 W 24 V DC
Power consumption VA
5.0 VA 24 V AC 50/60 Hz
Input protection type
Internal, electron
safety outputs
3 NO
safety inputs
2
Maximum line resistance
500 Ω
Input compatibility
Normally closed circuit complies with ISO 14119
The XC limit switch complies with ISO 14119
Mechanical contacts comply with ISO 14119
Normally closed circuit complies with ISO 13850
The Antivalent pair conforms to ISO 14119
OSSD pair complies with IEC 61496-1-2
3-wire proximity sensor PNP
Rated working current
5 A AC-1
3 A AC-15
5 A DC-1
3 A DC-13
control outputs
3 pulsed output
Input/output type
Semiconductor pulsed diagnostic output Z1, 20 mA
Conventional heating current
8 A
A fuse for use with a relay
10 A gG NO relay output circuit in accordance with IEC 60947-1
Minimum output current
10 mA for relay output
Minimum output voltage
15 V for relay output
Maximum response time on input open
20 ms
Rated insulation voltage
250 V (pollution level 2) in accordance with EN/IEC 60947-1
Rated impulse withstand voltage [Uimp]
4 kV overvoltage Class II conforms to EN/IEC 60947-1
Local signal indication
LED indicator (green) Power on:
LED indicator (red) error:
LED indicator (yellow) Starting:
LED indicator light (yellow)safety status:
LED indicator light (yellow)safety input S12:
LED indicator light (yellow)safety input S22:
Installation mode
35 mm DIN guide rail
depth
120 mm
height
100 mm
width
22.5mm
Net product weight
0.200kg
environment
standard
IEC 60947-5-1
IEC 61508-1 functional safety standard
IEC 61508-2 functional safety standard
IEC 61508-3 functional safety standard
IEC 61508-4 functional safety standard
IEC 61508-5 functional safety standard
IEC 61508-6 functional safety standard
IEC 61508-7 functional safety standard
ISO 13849-1 functional safety standard
IEC 62061 functional safety standard
Product certification
TUV
cULus
IP protection level
IP20 (screw terminal) complies with EN/IEC 60529
IP40 (case) in accordance with EN/IEC 60529
The IP54 (mounting area) complies with EN/IEC 60529
Storage ambient temperature
25... 85 °C
Relative humidity
5... 95% non-condensation
Packing unit
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
6.7cm
Package 1 Width
13.7cm
Package 1 Length
15.5cm
Package 1 Weight
270 g
Unit Type of Package 2
S03
Number of Units in Package 2
16
Package 2 Height
30 cm
Package 2 Width
30 cm
Package 2 Length
40 cm
Package 2 Weight
5.176kg
Unit Type of Package 3
P06
Number of Units in Package 3
128
Package 3 Height
75 cm
Package 3 Width
80 cm
Package 3 Length
60 cm
Package 3 Weight
50.772 kg