Electrical design | PNP/NPN; (configurable) |
---|---|
Output function | normally open / closed; (configurable) |
Communication interface | IO-Link |
Housing | Threaded type |
Dimensions [mm] | M18 x 1 / L = 60 |
Operating voltage [V] | 10...30 DC |
---|---|
Current consumption [mA] | < 15 |
Protection class | III |
Reverse polarity protection | yes |
Electrical design | PNP/NPN; (configurable) | |
---|---|---|
Output function | normally open / closed; (configurable) | |
Max. voltage drop switching output DC [V] | 2.5 | |
Permanent current rating of switching output DC [mA] | 100 | |
Switching frequency DC [Hz] | 300 | |
Notes on switching frequency [Hz] |
|
|
Short-circuit protection | yes | |
Overload protection | yes |
Switch point IO-Link [mm] | 2.4...12.1; (configurable) |
---|---|
Measuring range IO-Link [mm] | 1.3...13 |
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminum: 0.5 / copper: 0.4 | |
---|---|---|
Hysteresis [% of Sr] | 3...15 | |
Note on hysteresis |
|
|
Linearity error IO-Link [%] | ± 2; (of the final value of the measuring range) | |
Repeatability analog output [%] | ± 1; (of the final value of the measuring range) | |
Temperature coefficient [%/K vom MEW] | ± 0,3 | |
Temperature drift | ± 10 %; (of the final value of the measuring range) |
Communication interface | IO-Link | ||||||||
---|---|---|---|---|---|---|---|---|---|
Transmission type | COM2 (38,4 kBaud) | ||||||||
IO-Link revision | 1.1 | ||||||||
SDCI standard | IEC 61131-9 | ||||||||
Profiles | Smart Sensor: Identification and diagnosis; Multi-channel, two setpoint switching sensor, type 0 Generic Profiled Sensor; Teach Channel | ||||||||
SIO mode | yes | ||||||||
Required master port class | A | ||||||||
Min. process cycle time [ms] | 3.2 | ||||||||
IO-Link process data (cyclical) |
|
||||||||
IO-Link functions (acyclical) | switching cycles counter; switch-on cycle counter; operating hours counter; internal temperature; application specific tag | ||||||||
Supported DeviceIDs |
|
||||||||
Note |
|
Ambient temperature [°C] | -40...85 |
---|---|
Protection | IP 65; IP 66; IP 67; IP 68; IP 69 |