Wide Angle Analog Panel Ammeter 96*96mm , Analog Ac Amp Panel Meters Wtih Rectifer Ct500/5a
1. Product Introduction:
This type of meters are analog electric measuring instruments, widely used for measuring AC/DC current, voltage, frequency, power,power factor, insulation resistance and synchronous indicating in AC/DC transmitting & distributing power system, switchboard, other electric & non-electric instruments.
Our 96*96mm & 72*72mm squre meter, and 110*110mm, 80*80mm are round type meter improved in structure, material, seals according to environmental conditions & demands in marine industry, which let our meter have the ability of not only advanced technology, reasonable structure, good quality, but also good appearance, light weight, anti-mechanical force and different climate.
2. Technical Parameters:
Item |
Technical Data |
Standards |
Technical Standard |
GB/T7676-1998 |
IEC60092-50 |
Environmental Standard |
GB8355-1987 |
IEC92-504-74 |
Safety Standard |
GB4793-20 |
IEC61010 |
Working Temperature |
-40-65℃ |
|
Temperature Infulence |
-13-33℃, 100% comply with accuracy class |
|
Indicating Angle |
240°-270º (Synchroscope meter: 360º) |
|
Color of Shell |
Black/white,board frame, terminal plate: black |
|
Color of Dial Plate |
Black/white(other colors are available) |
|
Mounting |
Vertical Installation |
|
Dimension |
110*110mm, 80*80mm |
|
96*96mm, 72*72mm, 48*48mm |
|
Overshoot |
Less than 20% when scale reaches to 2/3 |
|
Insulation Withstand |
Circuit& shell: AC2600V/1 min(Water area) |
|
Vibration Resistance |
24.5m/s2 |
|
Impact Resistance |
147m/s2 |
|
Material |
Shell/terminal board: ABS; Cover: Transparent Glass |
3. Ordering Code:

4. Main Characteristic:
- Moving coil bearing & shaft tip structure.
- Advanced converter & indicating integrated structure, which make high measuring accuracy and big corner; Frequency accuracy: 0.5%; power factor meter: 2.5%, others are 1.5%;
- Moving Coil structure, good linear scale and undisturbed by outer magnetic fields;
- Shell consist of flame tetardant material, withstand voltage of shell & circuit: AC2000V/1 minute, protection class: IP52;
- Appearance use universal structure, modulus 12. squre type, easy to read scale
5. Wiring Diagram

5. Certificates:

6. Our Advantage:
- Standard dial: Utilize the white printed alloy-aluminum materials with black scale, value, units and technique symbols, dial with special requirements are available;
- Terminal Protection: Insulated protective cover with different shapes can be customized to provide a better safety level;
- Change the dial of meters easily: Open the seal on housing, then insert or pull the dial out;
- Certificate: CCS certificate can match marine standard application;
- Insulation test: All meters will make insulation test before shipment, tested voltage: Under 2500V and 50Hz for 1 minute.