Item | Technical Data | Standards |
Technical Standard | GB/T7676-1998 | IEC60092-50 |
Environmental Standard | GB8355-1987 | IEC92-504-74 |
Safety Standard | GB4793-20 | IEC61010 |
Working Temperature | -40-65℃ | |
Temperature Infulence | -13-33℃, 100% comply with accuracy class | |
Indicating Angle | 240°-270º (Synchroscope meter: 360º) | |
Color of Shell | Black/white,board frame, terminal plate: black | |
Color of Dial Plate | Black/white(other colors are available) | |
Mounting | Vertical Installation | |
Dimension | 110*110mm, 80*80mm | |
96*96mm, 72*72mm, 48*48mm | ||
Overshoot | Less than 20% when scale reaches to 2/3 | |
Insulation Withstand | Circuit& shell: AC2600V/1 min(Water area) | |
Vibration Resistance | 24.5m/s2 | |
Impact Resistance | 147m/s2 | |
Material | Shell/terminal board: ABS; Cover: Transparent Glass |
2). Indicating Angle:90°
3). Measurement: Frequency in power system
1. With transducing 4-20mA output, accuracy class: 1%;
2. Out of specification: Mark red or Red pointer, pls specify;
3. Black/black color are both workable, and also inner illumination.