Main Performance and Parameters:
Parameters Items | GY1331UV40 | GY1359UV60 |
Rated Power | 40W | 60W |
Input Voltage | AC220-240V 50/60 Hz | |
Power Factor | ≥0.9 | |
UV-C Light Type | Philips TUV PL-L UV-C Light | |
Peak Wavelength | 253.7 nm | |
Light Source Life | 10000H | |
Disinfection Type | Common bacteria, viruses, and other microorganisms | |
Recommended Using Area Dimension | 10-15m² | 15-20m² |
Recommended Filter Replacement Frequency | 3-6 months | |
Working Duration Limit | Available for long-term operation | |
IP Rating | IP20 | |
Electric Safety Class | CLASS I | |
Surface Treatment | Anti-corrosive powder coating | |
Dimension | 318*133*121mm | 638*133*121mm |
Net Weight | 2.1Kg | 3.8Kg |
Executive National Standard | GB28235;GB19258;Q/141000 GY008—2021 |
Troubleshooting:
SN | Fault Description | Cause of Fault | Troubleshooting Method |
1 | The power is on, the indicator light is off, and the fan is working normally | UV-C light is damaged | Replace with a new UV-C light |
2 | The power is on, the indicator light is off, and the fan does not work | The socket has no electricity, or the product switch is faulty | Check whether the socket is electrified. If the socket has electricity, check whether the input circuit such as the product switch is normal |
3 | The fan noise has increased significantly | Too much dust on the filter | Replace with a new filter |
UV Light Sanitizer UVC Disinfection Lamp Germicidal Lamp Ultraviolet Ozone Steriliser
Safe and effective Air Sterilization Equipment
GY1331UV, GY1359UV Series
Hidden UV-C Air Disinfection Lights
GY1331UV40/GY1359UV60 is the hidden UV-C light series for air disinfection. The product features a broad-spectrum disinfection effect. Tested by the Guangdong Detection Center of Microbiology, its disinfection rate of various types of bacteria, fungi, viruses, and so on, has reached more than 99%.
Sanitizing surfaces is only half of the battle against the spread of bacteria and viruses, That's why hospitals routinely use ultra-violet light technology to disinfect patient areas. The UVC air disinfection is designed to move air around a powerful UV-C light to destroy contaminants in your homes such as allergens, bacteria, germs, mold spores, and viruses that standard HEPA-style air filters often miss.
KILLS GERMS
- UV-C light helps kill airborne viruses such as influenza, staph, rhinovirus, and works with Titanium Dioxide to reduce volatile organic compounds
TRAPS ALLERGENS
- Pre-filter traps dust, pet hair, and other large particles while extending the life of the HEPA filter
REDUCES ODORS
- Activated charcoal filter helps to reduce unwanted odors from pets, smoke, cooking fumes, and more
ULTRA-QUIET MODE
- Ultra-quiet sleep mode helps you get a good night’s rest with cleaner air
ROOM SIZE
-GermGuardian Air Purifiers filter air in medium to large rooms and cover 743 sq. feet at 1 exchange per hour, 371 sq. feet at 2 exchanges per hour, 248 sq. feet at 3 exchanges per hour, and 153 sq. feet at 4.8 exchanges per hour
Troubleshooting:
SN | Fault Description | Cause of Fault | Troubleshooting Method |
1 | The power is on, the indicator light is off, and the fan is working normally | UV-C light is damaged | Replace with a new UV-C light |
2 | The power is on, the indicator light is off, and the fan does not work | The socket has no electricity, or the product switch is faulty | Check whether the socket is electrified. If the socket has electricity, check whether the input circuit such as the product switch is normal |
3 | The fan noise has increased significantly | Too much dust on the filter | Replace with a new filter |