UVC ultraviolet sterilization lamp 40w 60w UV-C light source hidden design
Safe and effective Air Sterilization Equipment
GY1331UV, GY1359UV Series
Hidden UV-C Air Disinfection Lights
Effectively inactivate bacteria, fungi, and viruses.
There are no side effects.
Pure physical inactivation, there is no secondary.
pollution to air and water by chemical inactivation.
UV-C light source hidden design, which is used at any time, no need to worry about UV hazards.
Advantages:
Hide the UV-C light source, no harm to people and objects
Active convection of the fan improves the sterilization efficiency and reduces the dead angle
40W and 60W power can provide enough 253.7-nanometer sterilization ultraviolet radiation.
Suitable for air disinfection and purification in daily indoor scenes, long-term work available.
Product Features
• The product has no working time limit and can work for a long time.
• UV-C "closed" cavity disinfection, safe and reliable.
• Active convection design, high disinfection efficiency.
• Branded light source to ensure a stable output of ultraviolet radiation.
• The power of the product is 40W and 60W, providing sufficient ultraviolet radiation for disinfection.
Main Performance and Parameters:
Parameters Items | GY1331UV40 | GY1359UV60 |
Rated Power | 40 W | 60W |
Input Voltage | AC220-240V 50/60 Hz | |
Power Factor | ≥0.9 | |
UV-C Light Type | Philips TUV PL-L UV-C Light | |
Peak Wavelength | 253.7 nm | |
Light Source Life | 10000H | |
Disinfection Type | Common bacteria, viruses, and other microorganisms | |
Recommended Using Area Dimension | 10-15m² | 15-20m² |
Recommended Filter Replacement Frequency | 3-6 months | |
Working Duration Limit | Available for long-term operation | |
IP Rating | IP20 | |
Electric Safety Class | CLASS I | |
Surface Treatment | Anti-corrosive powder coating | |
Dimension | 318*133*121mm | 638*133*121mm |
Net Weight | 2.1Kg | 3.8Kg |
Executive National Standard | GB28235;GB19258;Q/141000 GY008—2021 |
Tests have verified that the product can effectively kill the H1N1 virus,
Escherichia coli, Staphylococcus Albicans, and other harmful microorganisms in the air.
Work scenes
This product is suitable for indoor places such as restaurants, cafes, bars, shopping malls, schools, offices, hospitals, and long-distance buses, buses, and other vehicles to disinfect and purify the air.
Troubleshooting:
SN | Fault Description | Cause of Fault | Troubleshooting Method |
1 | The power is on, the indicator light is off, and the fan is working normally | UV-C light is damaged | Replace with a new UV-C light |
2 | The power is on, the indicator light is off, and the fan does not work | The socket has no electricity, or the product switch is faulty | Check whether the socket is electrified. If the socket has electricity, check whether the input circuit such as the product switch is normal |
3 | The fan noise has increased significantly | Too much dust on the filter | Replace with a new filter |