Specifications
Brand Name :
Dimed
Model Number :
Cherylas
Certification :
CE
Place of Origin :
China
MOQ :
1 piece
Payment Terms :
Western Union, T/T, MoneyGram
Supply Ability :
50pcs/Month
Packaging Details :
Retail packing
wavelength :
1470nm
Maximum Power :
15w/30w
Operation Mode :
CW,Single Or Repeat Pulse
Pulse Duration :
10us-3s
Control Mode :
True Color Touch screen
Transmission System :
Medical Fibers With SMA905 Connector
Weight :
11KG
Application :
Varicose vein ,saphenous veins
Description

Disc Herniation Spinal Disc Diode Laser PLDD Surgery Machine Hardly Bleeding Local Anesthesia

PLDD is a minimally invasive treatment option for patients with low back pain caused by herniated disc (slipped disc). It is performed under local anaesthesia. A laser fibre is inserted percutaneously (through skin) into the nucleus pulposus through a micro-needle under X-Ray guidance without any open surgical wound.

Laser energy is delivered to the nucleus pulposus, results in vaporisation of water content and reducing internal disc pressure. A reduction of intradiscal pressure causing the herniated part of the disc to recede toward the centre of the disc, thus leading to reduction of nerve root compression. Patients can feel immediate relief of radicular pain

Spinal Disc Herniation PLDD Laser Equipment Hardly Bleeding Local Anesthesia

Operated with 400um/600um fiber optic, Chearylas 1470nm laser system is a versatile, multifunctional
medical diode laser machine ideal for minimal invasive PLDD.

The Cherylas 1470nm, with higher water absorption, enables precision ablation and highly localized heating, being advantageous around critical structures. thanks to its outstanding interaction in water and haemoglobin and moderate penetration depth into disc tissue, enables procedures to be carried out safely and accurately,especially in proximity of delicate anatomical structures.

Specifications

Laser Type GaAIAs Diode Laser
Wavelength 1470nm
Peak Power 15w
Operation Mode CW, Single / Repeat Pulse
Pulse Duration 10us-3s
Repetition Rate 0.2Hz-50KHz
Pilot Beam Red Diode Laser of 650nm, Power<5mw
Control Mode High resolution 7inch Touch screen (600*1024px)
Transmission System Medical Fibers With SMA905 Connector
Dimensions 380(W)*430(L)*220(H)mm
Weight 11KG

Benefits
Perfect tissue effect
Micro-invasive percutaneous access
The procedure is accompanied by minimal pain
The procedure can be performed under local anesthesia
No risk of scarring
Faster return to normal activity - in most cases the patient does not require a stay in a rehabilitation clinic

High Quality Laser Diode Technology

Laser diodes are the heart of the laser unit and have been selected for high levels of quality, efficiency and reliability. Featuring solid state technology, they are manufactured in Germany by Lumics, Inc. which is a recognized worldwide leader for producing the highest performing diodes. This ensures superior operating life resulting in long term savings in operating costs.

Maximum Range Of Power(Watts )Level

Multiple power (watts) levels are available in different power configuration models from 1-60 watts. These power (watts) levels can provide significantly more energy than other medical & surgical diode lasers. The higher power (watts) level laser models provide faster treatment times and delivery of optimal energy dosages, an enhanced ability to treat difficult conditions, and enhanced clinical outcomes.

Interactive User Interface

Treatments can be administered and managed with three options: 1) Manual Protocols using the power level, operating mode and timer selections; 2) Preset Protocols that utilize a built-in database of protocols that are organized by anatomy and condition; 3) Custom Protocols that allows the user to create their own unique protocols.

Choice Of Different Operating Modes

Two operating modes Continuous Wave (CW) or Pulsed Modes (50khzFrequencies) are built into the diode laser equipment. The specific power level (watts) can be adjusted through progress bar on the color touchscreen. The Pulsewidth can be operated using different units, like you can set duration 50us, interval 1ms.

Medical Diode Laser Machine Of Excellent Design

S-shape design to protect laser moduel from a damage caused by accidental impact.

Accessories

Dimed providing a full set of high quality standard and optional accessories, such as puncture needle, Y-valve,optical fiber, safety goggles, footswitch, fiber

cutter, carry case, cart and etc.

Puncture Needle
Optical Fiber 400um
Y- Valve

Send your message to this supplier
Send Now

Spinal Disc Herniation PLDD Laser Equipment Hardly Bleeding Local Anesthesia

Ask Latest Price
Brand Name :
Dimed
Model Number :
Cherylas
Certification :
CE
Place of Origin :
China
MOQ :
1 piece
Payment Terms :
Western Union, T/T, MoneyGram
Contact Supplier
Spinal Disc Herniation PLDD Laser Equipment Hardly Bleeding Local Anesthesia

Qolight Technology Co., Ltd

Active Member
4 Years
jiangxi, wuhan
Since 2020
Business Type :
Manufacturer
Total Annual :
1000000-2500000
Employee Number :
>100
Certification Level :
Active Member
Contact Supplier
Submit Requirement