Portable diode laser therapy equipment for back pain and herniated disc
When should consider minimally-invasive PLDD procedure
The PLDD procedure is specifically designed and developed for the cervical and lumbar indications, including:
Cervical problems
One or more cervical disc herniations
Neck pain, shoulder pain, bilateral numbnesss,
dizziness and other symptoms.
Lumbar problems
Restrictive disc on CT or MRI
No intervertebral calcification, free, prolapse
Straight leg elevation test positive
Six weeks of conservative treatent is invalid
The principle of PLDD
In this procedure, laser energy is transmitted through a thin optical fiber into the disc. The aim of PLDD is to vaporize a small portion of the inner core. The ablation of a relatively small volume of the inner core results in an important reduction of intra-discal pressure, thus inducing reduction of disc herniation.
PLDD is the minimally-invasive medical procedure developed by Dr. Daniel S.J. Choy in 1986 that uses a laser beam to treat back and neck pain caused by a herniated disc.
Percutaneous laser disc decompression (PLDD) is the utmost minimally invasive percutaneous laser technique in the treatment of the disc hernias, cervical hernias, dorsal hernias (except for the segment T1-T5), and lumbar hernias. The procedure uses the laser energy to absorb the water within the herniated nucleus pulposus creating a decompression.
The PLDD treatment is performed on an outpatient basis using only local anesthesia. During the procedure, a thin needle is inserted into the herniated disc under x-ray or CT guidance. An optical fiber is inserted through the needle and laser energy is sent through the fiber, vaporizing a tiny portion of the disc nucleus. This creates a partial vacuum which draws the herniation away from the nerve root, thereby relieving the pain. The effect usually is immediate.
Specifications
Laser Type | GaAIAs Diode Laser |
Wavelength | 1470nm |
Peak Power | 15w |
Operation Mode | CW, Single / Repeat Pulse |
Pulse Duration | 10us-3s |
Repetition Rate | 0.2Hz-50KHz |
Pilot Beam | Red Diode Laser of 650nm, Power<5mw |
Control Mode | High resolution 7inch Touch screen (600*1024px) |
Transmission System | Medical Fibers With SMA905 Connector |
Dimensions | 380(W)*430(L)*220(H)mm |
Weight | 11KG |
Benefits
Perfect tissue effect
Micro-invasive percutaneous access
The procedure is accompanied by minimal pain
The procedure can be performed under local anesthesia
No risk of scarring
Faster return to normal activity - in most cases the patient does not require a stay in a rehabilitation clinic
Accessories
Dimed providing a full set of high quality standard and optional accessories, such as puncture needle, Y-valve,optical fiber, safety goggles, footswitch, fiber
cutter, carry case, cart and etc.
