Technical Specifications
Item | Parameters |
Model | DS380 |
Principle | Fluorescence analysis method |
Measuring range | 0~20mg/L or 0-200% saturation |
Response time | 3 sec |
Accuracy | 1% |
Protection level | IP68 |
Installation | Submersible |
Temperature sensor | NTC |
Temperature range | 0~50°C |
Temperature accuracy | ±0.2°C |
Output | Support RS-485, MODBUS protocol |
Power supply | DC 6~12V, current <50mA |
Size | Φ26*155 mm |
Probe cable length | Default 5 m, customized 10m, 15 m and 30 m cable |
Fluorescent cap life | 1 year |
Maximum working pressure | 3bar |
Housing material | SS316/Titanium alloy |
Sensor maintenance
1) Sensor outer surface:
Clean the outer surface of the sensor with tap water. If there is still debris left, wipe it with a soft cloth. For some stubborn dirt, add some household washing liquid to the tap water to clean it.
2) The outer surface of the fluorescent cap:
Remove the protective cover at the front end of the sensor, rinse the dirt on the sensor window with clean water, and finally cover the cover; if you need to wipe, use a soft cloth and carefully wipe the force direction.
Dimensions:
Photos