Single-Phase Centralized Control Centralized Power Supply For Fire Emergency Lighting
Product Overview
The main components of the company EPS include: battery pack, IPM intelligent module, charger, master control panel, LCD (ICD) display current / voltage / temperature detection circuit, interlock switching circuit, alarm circuit, etc.
The EPS can be civil air defense channels, underground facilities, hospitals, operating rooms, government organs, large supermarkets, shopping malls and schools.Square, stations, parks, sports venues, convention and exhibition center securities trading halls and other public places to provide fire emergency lighting power, as well as emergency power power for elevators, spray pumps, curtain doors, water pumps, fans, monitoring devices, military radar, on-board mobile sources, system and other equipment of financial institutions.
Model Meaning
D | KW |
EPS Single-Phase (Lighting) Emergency Power Supply | Power Rating (KW) |
Product Profile
Qualification
Model | (0.5kw~3kw) (4kw~15kw) | |
Input | City Power Voltage | 220v±15% (It Can Be Set Up On Customer Request) |
Power Frequency | 50hz±5% | |
Input Currenton | Input The Current Standard Value Of x1.2 x | |
Direct Voltage | 48v 192v | |
Double Road Mutual Investment | (It Can Be Added According To The Customer Design Requirements) | |
Output | Output Voltage | Normal State: Consistent With The Municipal Electricity |
Emergency Status: 220v ± 3% | ||
Output Frequency | Normal State: Consistent With The Municipal Electricity | |
Emergency Status: 50hz ±, 5% | ||
Output Loop | Three Roads (Which Can Be Added According To Customer Design Requirements} | |
Outputs The Loop Type | Continuous, Non-Sustainable, Fire Control Linkage Type | |
Productiveness | Emergency Time 90%, Municipal Power Power Supply 100% | |
Discharge Waveform | Pure Sine Wave | |
Switching Time | ≤3秒(It Can Be Specially Customized For 100 Ms Or 0 Ms) | |
Overloading Characteristic | Normal 60 Seconds At 120%; 30 Seconds At 150% | |
Stand-By Time | 90 Minutes (Configurable According To Customer Request) | |
Storage Battery | Valve-Free Lead-Acid Battery | |
Defencive Function | Over-Temperature, Short-Circuit, Over-Pressure, Over-Current Protection | |
Situation Display | Large-Screen Lcd Lcd Display | |
CI | Rs485 / Rs232, Communication Protocol: Modbus (Customer Selection Item) | |
Noise | Normal State: No Noise, Emergency State: w55db | |
Ambient Temperature | -25°c~40℃ | |
Relative Humidity | 10-90% | |
Altitude | ≤2000m;Power Reduction Shall Be Used At 2000m | |
Adapt To Load | Suitable For a Variety Of Single-Phase And Lighting Class Negative Planting |
Size
Ts | Output Power Kw | Appearance Size (Mm) Wide x x Deep x High | Weight(Kg) | Install |
0.5kw | 0.5 | 500x250x800 | 75 | Nested |
1kw | 1.0 | 500x250x800 | 130 | Hang Type |
1.5kw | 1.5 | 600x400x1200 | 210 | |
2kw | 2.0 | 600x400x1200 | 230 | |
3kw | 3.0 | 600x400x1200 | 360 | |
4kw | 4.0 | 700 x450x 1500 | 460 | |
5kw | 5.0 | 700x450x1500 | 590 | Floor Type |
6kw | 6.0 | 700 x450x 1500 | 750 | |
7kw | 7.0 | 800x600x2000 | 900 | |
8kw | 8.0 | 800x600x2000 | 1000 | |
9kw | 9.0 | 800x600x2000 | 1100 | |
10kw | 10.0 | 800x600x2000 | 1200 |
All model specifications and sizes can be ordered according to customer request.
When Used For Emergency Lighting, Eps Line And Type, Switch Wiring
Output Line Code | Instruction | Mode Of Connection |
l | Municipal Power Has Output, No Municipal Power Has Output (With Emergency Power Supply) | i(Continuous Output) |
l1 | There Is No Output Of Market Power, No Market Power Transmission (There Is Emergency Power Supply) | Ii (Nonsustainable Output) |
l2 | Municipal Power Has Output, No Market Power, No Output (No Emergency Power Supply) | Iii (General Distribution Output) |
l3 | When There Is Municipal Power, There Is No Municipal Power, And No Municipal Electricity Is Controlled By Fire Control Linkage Output | Iv (Fire Linkage Output) |
l4 | Normal No Output, Emergency By The Fire Linkage Control Output | v(Fire Linkage Output) |
n | ||
Pe |
Attended Mode
Note; L1, L2, L3 are not available in each EPS but made according to the design requirements.