ATS smart UPS input mains output power distribution
Product parameter
Configuration and parameters | |
Rated current | 100~630A |
Input voltage | Optional AC110- AC450V or DC -48V |
Input frequency | 47. 5HZ-52. 5HZ |
Input circuit | Single power input/dual power input/three power input |
Enter ATS | Optional 63-400A |
Mains output branch | Can be customized according to user needs |
UPS input and output | 1 unit/2 units UPS or other |
UPS output branch | Can be customized according to user needs |
Monitor display | Direct color touch screen, power meter |
LCD touch screen size | 7 inch 10 inch |
Branch switch status monitoring and alarm | Optional, this must be equipped with a touch screen |
Branch circuit voltage and current monitoring, alarm | Optional, this must be equipped with a touch screen |
Recite | Support MODBUS485 |
Lightning protection | Optional B grade, C grade, B+C grade |
Air switch status indicator for each channel | Optional LED light/16mm cut-out light/ring light |
Temperature and humidity | Match |
Access control | Match |
Automatic lighting | Match |
Relative humidity | 0-95% non-condensing |
Altitude | <2000m |
Protection level | IP20 |
Grounding system | TN-S (three-phase five-wire) |
Cabinet color | Default black (RAL9005) |
Optional telecom gray (RAL7035) / customer specified color number | |
Cabinet door | Default net door, single door in front and double door in back |
Optional glass door'Front single door, rear single door | |
Cabinet material | The default plate is 1.0, the vertical beam is 2.0, the beam 1.2 is 500KG |
Optional plate 1.2, vertical beam 2.0, cross beam 1.5, load-bearing 800KG | |
Optional brand cabinet/customer-supplied cabinet |
Overview
Hailianxin i-ATS intelligent switching cabinet adopts Schneider Wangao series ATS and intelligent control panel independently developed by Hailianxin. It is suitable for two power sources (common power supply and backup power supply) with AC 50HZ, rated voltage 690V and below, and rated current From 40A to 800A. Automatic switching between power supplies occurs due to an abnormality in one power supply. The main features of this device are: automatic switching, automatic detection, and automatic display functions. Mechanical interlocking and electrical interlocking dual protection functions, energy saving and no noise during operation, can implement automatic switching and automatic recovery, automatic switching and non-automatic recovery, loss of voltage, undervoltage, phase failure protection, manual/automatic conversion, and the main body of the switch The switching time is less than 80mS, the intelligent controller is adjustable from 0-30s, and the volume is small, only one third of the traditional device. The switching capacity is large and can be switched in four levels. The PC-level intelligent dual-power automatic switch is currently the most ideal electrical product for two-way power switching. It has been selected by the project and is the leading product in the new century. It will be more widely used in industrial and civil buildings.
Application scenario
1. Generator set, UPS pre-distribution, EPS power pre-distribution, etc.
2. Hospitals, shopping malls, banks, chemicals, metallurgy, high-rise buildings and other important occasions where power is not allowed to be cut off.
Characteristics and value
◆ The generator set is automatically switched on: When the mains power fails, the control cabinet will issue a command to start the generator set.
◆ Automatic switching of power supply: After the mains power fails and the generator set runs stably, the control cabinet will automatically switch to the power supply state of the generator set. When the mains power is restored and stabilized, the control cabinet automatically switches back to the mains power supply state.
◆ Automatic shutdown of the unit: When the mains power is restored and stable, the control cabinet will automatically switch back to the "mains closed" state, and the unit will automatically stop after the set shutdown and cooling time.
◆ Unit automatic protection: When the unit has over-speed or under-speed), it will alarm and shut down.
◆ Manual operation of the generator set: When the generator set needs to be manually operated, the start and shutdown of the generator set can be controlled through the manual and stop buttons.
◆ Ats manual operation: When the control cabinet needs to be manually switched, a manual wrench can be used to switch the ats switch to enter the "mains closed" or "machine combined brake" state.
◆ Automatic floating charge: Built-in automatic floating charger, as long as there is mains input, the battery will be automatically floated and charged.
Extended functions
1. Water temperature and oil pressure probe can be configured to realize the high water temperature and low oil pressure protection of the unit. When the unit has low oil pressure or high water temperature, the control cabinet will alarm and shut down.
2. Servo motor or electronic governor can be configured to realize the idle speed control of the unit: After the unit starts automatically, it will increase the speed after the set idle running time. When the unit is stopped, the speed will decrease first, and then run at low speed. Stop after idle running time. Support throttle servo motor and electronic governor.
3. The parameters can be set to meet the control needs of different occasions. (The main parameters that can be set are system frequency, startup and shutdown time, cooling time, warm-up time)