Product Overview:
According to the development demand of Chinese electric power, the power supply products specially designed for power plants, substations and distribution have double conversion on-line and zero conversion functions. Mainly used for power telemetry, RTU, power carrier, power monitoring and so on. When the mains is normal, the single-phase 220V (or three-phase 380V) is isolated and filtered through the inverter to provide stable power supply to the load. If the INPUT of AC power grid is abnormal or power is cut off, the backup DC panel of power system will be powered by reverse diode inverter. When dc panel undervoltage or power, static switch to bypass power supply; When the mains returns to normal, it automatically switches to the mains inverter. If the inverter is overloaded or faulty, it switches to bypass mode and sends a warning signal. Widely used in power plants, substations, distribution stations, etc.
Product technical parameters
Type | 3GDL-10 | 3GDL-15 | 3GDL-20 | 3GDL-30 | 3GDL-40 | 3GDL-50 | 3GDL-60 | 3GDL-80 | |
capacity | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 50KVA | 60KVA | 80KVA | |
Rate power | 8KW | 12KW | 16KW | 24KW | 32KW | 40KW | 48KW | 64KW | |
AC Input | voltage | 380V±25% | |||||||
frequency | 50HZ/60HZ±5% | ||||||||
THDI | 3% | ||||||||
Input power factor | ≥0.85(6 pulse rectifier) ≥0.99(12 pulse rectifier plus filter) | ||||||||
Dual mains input | Supported (Optional) | ||||||||
Dc input voltage | 220VDC(187V~265V) or 110VDC(93V~133V), the voltage range can be modified according to customer requirements | ||||||||
output | voltage | 220VAC | |||||||
output stability | ±1%(steady state load), ±3%(load fluctuation) | ||||||||
frequency | 50/60Hz | ||||||||
power factor | 0.8 | ||||||||
overload capacity | 115% normal operation; By 125% for 10 min; 1 min 150%; 200%1s | ||||||||
full load efficiency | 91%-95% | ||||||||
displayer | LCD | UPS status and operation instructions in Chinese | |||||||
Input voltage, output voltage, current, frequency and discharge value, fault display, warning | |||||||||
LED | UPS transfer status | ||||||||
choose accessories | communication interfaceRS232, RS485, dry contact interface (passive node), optional SNMP network monitoring card | RS232, RS485, dry contact interface (passive node), optional SNMP network monitoring card | |||||||
Function of cabinets | Input and output power distribution cabinet (feeder cabinet), harmonic compensation cabinet, lightning protection device, input and output isolation cabinet, bypass voltage regulator cabinet (cabinet size can be designed according to requirements) | ||||||||
operating environment | temperature | 0℃~40℃ | |||||||
humidity | 30% ~ 90% without any condensation | ||||||||
altitude | ≤5000米 | ||||||||
weight KG | Varies with product model | ||||||||
Main engine appearance dimensions | Varies with product model |
Product performance:
Special UPS, DBW bypass regulator cabinet and PD series feeder cabinet are power supply products specially designed by Shenzhen Shande Power Supply Company for power plant, substation and distribution according to the development demand of China's electric power. They have double conversion on-line type and zero conversion function. Mainly used for power telemetry, RTU, power carrier, power monitoring and so on. When the mains is normal, the single-phase 220V (or three-phase 380V) is isolated and filtered through the inverter to provide stable power supply to the load. If the INPUT of AC power grid is abnormal or power is cut off, the backup DC panel of power system will be powered by reverse diode inverter. When dc panel undervoltage or power, static switch to bypass power supply; When the mains returns to normal, it automatically switches to the mains inverter. If the inverter is overloaded or faulty, it switches to bypass mode and sends a warning signal.
Applicable place:
Power plants, substations, distribution stations, etc.
Main performance features: