ONE 1200W 12V/24V To 220V DC To AC Single Phase Off Grid Pure Sine Wave Solar Inverter
Model : LI-12212
Continuous stable output voltage: No matter how low or how high the AC input voltage is, with voltage stabilizer our inverter provides standard 110V or 220V stable output, which keeps the loading works stably. Wide stabilizing range of AC input optional.
----------------------------------
Others: Only a few inverter in the market has stabilizer technology, even they have, they can only
provide short time stabilization but not continuously. So the loading can work in short time stably only but not long time. Or their stabilizing range is not wide as ours.
True Intelligent Cooling Fan
Dual ball bearing intelligent cooling fan, through built-in realtime temperature monitoring probe it can speed up or slow down according to the working temperature of inverter, in order to reduce the consumption of power. Sand proof design, to keep cooling fan works properly in outdoor environment.
LI Series Low Frequency Pure Sine Wave Inverter (220V) | |||||||||||||
Model | LI-351 | LI-501 | LI-601 | LI-102 | LI-152 | LI-202 | LI-302 | LI-502 | LI-702 | LI-103 | LI-153 | LI-203 | |
Rated Power | 350W | 500W | 600W | 1KW | 1.5KW | 2KW | 3KW | 5KW | 7KW | 10KW | 15KW | 20KW | |
Peak Power | 700W | 1000W | 1200W | 2KW | 3KW | 4KW | 6KW | 10KW | 14KW | 20KW | 30KW | 40KW | |
Nominal battery voltage | 12VDC | 12VDC/24VDC | 24VDC/48VDC | 48VDC | 96VDC | 192VDC | |||||||
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) / 84-120VDC (96V) / 168-240VDC (192V) | |||||||||||
AC Mains input range | (220/230/240VAC) 140-275VAC | 170-250VAC | |||||||||||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition) | ||||||||||||
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) / ≤84VDC (96V) / ≤168VDC (192V) alarm | |||||||||||
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) / ≤80VDC (96V) / ≤160VDC (192V) automatic shutdown | ||||||||||||
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) / ≥120VDC (96V) / ≥240VDC (192V) alarm | ||||||||||||
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) / ≥136VDC (96V) / ≥272VDC (192V) automatic shutdown | ||||||||||||
Over load protection | 110% more than rated capacity, automatic shutdown | ||||||||||||
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown | ||||||||||||
Short circuit protection | Automatic shutdown | ||||||||||||
Output | Transfer efficiency | ≥85% | |||||||||||
Output voltage | (DC battery mode) 220/230/240VAC±2% | ||||||||||||
Output frequency | (DC battery mode) 60/50Hz±1% | ||||||||||||
Output wave form | Pure sine wave | ||||||||||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | ||||||||||||
AVR output stablizer | AC mains<140VAC±5% swtich to DC battery mode, AC mains>150VAC ±5% return to AC mains mode; | ||||||||||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | |||||||||||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage | |||||||||||||
Output frequency | (AC mains mode) automatic tracing from AC input | ||||||||||||
Other | Transfer time | ≤10ms | |||||||||||
Display | LCD Display with function buttons | ||||||||||||
Cooling system | Intelligent cooling fan control system | ||||||||||||
≤42℃ slow fan, ≥45℃ fast fan | |||||||||||||
AC Charger | AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V)/108.8-113.6VDC(96V)/217.6-227.2VDC(192V) | |||||||||||
AC charging current | Steady 15A | ||||||||||||
AC over charge protection | Battery ≧16V (12V) ≧32V (24V) ≧64V (48V) ≧128V (96V) ≧256V (192V), stop charging after 60s alarm | ||||||||||||
Working mode (Optional) | 01 | AC mains priority | |||||||||||
Always use AC mains as priority input to provide AC output and automatically charge the battery, | |||||||||||||
only stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off | |||||||||||||
02 | Energy saving | ||||||||||||
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on | |||||||||||||
03 | DC battery priority | ||||||||||||
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts DC to | |||||||||||||
AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC output and | |||||||||||||
automatically start charging the battery (for 24V/48V/96V/192V system, multiply by 2/4/8/16 accordingly) | |||||||||||||
Comnunication | RS-232/USB/SNMP(additional option) | ||||||||||||
Environment | Temperature | -20~75℃ | |||||||||||
Humidity | <95% | ||||||||||||
Appearance | Product size (mm) | 300*240*120 | 410*225*410 | 485*300*655 | |||||||||
Packing size (mm) | |||||||||||||
Net Weight (kg) | 7.2 | 7.5 | 7.5 | 8.7 | 23.5 | 25.5 | 28.8 | 55 | 56 | 85 | 105 | 125 | |
Gross Weight (kg) | |||||||||||||
*Product specifications are subject to change without further notice |
Adjustable mains priority and inverter priority mode:
Mains priority: When AC mains and DC battery are connected at the same time, inverter chooses AC mains for priority AC output.
Inverter priority: When AC mains and DC battery are connected at the same time, inverter converts DC battery power for priority AC output.
Customers can choose mains priority or inverter priority mode according to their own needs, and can switch them at any time.