CE & FCC 6kw Single output off grid solar inverter 48vdc 220vac frequency inverter for solar power system
Model : GI-60248
An individual 64-bit DSP control chip, more text samples and control functions
The detection and control program is written into the DSP chip. The results are fetched by DSP chip and the Power inverter is controlled by DSP chip. The advantage is that the value is accurate(by effective value). Tolerance is less than 0.01%
Photoelectricity isolation circuitry technology:
It can detect and modulate the pulse width of boost circuit, reduce the EFT(Electric Fast Transient) and raise anti-interference.
B.The Power inverter without this function. Which will cause high EFT(Electric Fast Transient) and low anti-interference.
The whole series with automatic AC charger and automatic AC mains switch function. Switch time within 4ms.
GI Series Low Frequency Pure Sine Wave Inverter (220V) | ||||||||
Model | GI-102 | GI-152 | GI-202 | GI-302 | GI-402 | GI-502 | GI-602 | |
Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |
Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | |
Nominal battery voltage | 12/24VDC | 12/24/48VDC | 24VDC/48VDC | |||||
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) | ||||||
AC Mains input range | 170-275VAC (220/230/240VAC)±4% | |||||||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) | |||||||
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm | ||||||
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown | |||||||
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm | |||||||
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown | |||||||
Over load protection | 110%<loading<150%, shutdown after 60s alarm, loading>150%, shutdown after 20s alarm | |||||||
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown | |||||||
Short circuit protection | Automatic shutdown | |||||||
Output | Transfer efficiency | ≥92% | ||||||
Output voltage | (DC battery mode) 220/230/240VAC±2% | |||||||
Output frequency | (DC battery mode) 60/50Hz±1% | |||||||
Output wave form | Pure sine wave | |||||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | |||||||
AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; | |||||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | ||||||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage | ||||||||
Output frequency | (AC mains mode) automatic tracing from AC input | |||||||
Other | Transfer time | ≤4ms | ||||||
Display | LCD Display with function buttons | |||||||
Cooling system | Intelligent cooling fan control system | |||||||
≤42℃ slow fan, ≥45℃ fast fan | ||||||||
AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Calcium(open) / | ||||||
Deep sulphation cycle 15.5 for 4 hrs | ||||||||
AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) | |||||||
AC charging current | 0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages adjustable option | |||||||
3 Stages charging | Boost charging, direct charging, float charging | |||||||
AC over charge protection | Battery voltage ≧16VDC (12V) ≧32VDC (24V) ≧64VDC (48V), stop charging after 60s alarm | |||||||
Working mode (Optional) | 01 | AC mains priority | ||||||
Always use AC mains as priority input to provide AC output and automatically charge the battery, only | ||||||||
stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off | ||||||||
02 | Energy saving | |||||||
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on | ||||||||
03 | DC battery priority | |||||||
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts | ||||||||
DC to AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC | ||||||||
output and automatically start charging the battery (for 24V/48V system, multiply by 2/4 accordingly) | ||||||||
Comnunication | RS-232/USB/SNMP(additional option) | |||||||
Environment | Temperature | -20~75℃ | ||||||
Humidity | <95% | |||||||
Appearance | Product size (mm) | 430*310*270mm | 600*270*200mm | |||||
Packing size (mm) | 540*350*300mm | 720*310*270mm | ||||||
Net Weight (kg) | 15kg | 17kg | 24.5kg | 29kg | 44kg | 48.1kg | 49.5kg | |
Gross Weight (kg) | 16.5kg | 19kg | 27kg | 31kg | 46kg | 50.1kg | 52.2kg | |
*Product specifications are subject to change without further notice |
Question & Answer:
Q: How to choose a right Power inverter?
A:Tell us your demand, then our sales will recommend a suitable Power inverter to you.
Q: What's the different between Power inverter and solar Power inverter?
A: Power inverter is only accept AC input, but solar Power inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.
Q: How about the delivery time?
A: 5 days for sample; 20 days for bulk order.
Q: What is the warranty of Power inverter?
A: One year warranty.
Q: How to solve the technical problem?
A: 24 hours after-service consultancy just for you and to make your problem to solve easily.