Specifications
Brand Name :
DLX
Model Number :
Type k Thermocouple extension wire
Certification :
CE,ROHS
Place of Origin :
China
MOQ :
5
Payment Terms :
L/C, T/T, Western Union, MoneyGram
Supply Ability :
300 tons per month
Delivery Time :
5-21 days
Packaging Details :
Spool package with Carton box, Coil package with polybag
Product name :
Thermocouple K extension wire
Color :
bright
Certificate :
ISO9001
Temperature range :
32 to 392F (0 to 200C)
EMF tolerance :
+/- 2.2C or +/- .75%
Grade :
Extension Grade Type K
Positive :
Ni-cr
Negative :
Ni-si
Special Limits of Error :
+/- 1.1C or 0.4%
Description

Thermocouple Type K Extension Cable for Temperature Compensation

The compensation wire models are divided into SC, KC, KX, EX, JX, TX according to the product variety.

Among them: a) The first letter of the model corresponds to the graduation number of the thermocouple;

b) The letter "X" represents the extended compensation wire (type)

c) The letter "C" represents the compensation type compensation wire (type)

Note: SC type compensation wires can be equipped with R-type indexing thermocouples.

  • Thermocouple Extension Wire

Type K Extension Cable 0.5*2 red black pvc insulation with pvc sheath. The conduct is thermocouple type K material which is nickel-chrome with nickel-siliconor nickel-aluminum. The construction is similar to pair instrumentation cable but the conductor material is different. Thermocouples are used in processes to sense temperature and is connected to the pyrometers for indication and control. The thermocouple and pyrometer are electrically conducted by thermocouple extension cables / thermocouple compensating cables. The conductors used for these thermocouple cables are required to have similar thermo-electric (emf) properties as that of the thermocouple used for sensing the temperature.

Basically, Fine Wire Thermocouple grade wires are used to make sensing points of thermocouples. However, a Thermocouple Extension Wire is only used to extend a thermocouple signal back from the probe to the instrument reading it. A thermocouple Extension Cable is used in lower ambient temperatures. It may pass a signal representing a higher temperature than it received from the probe. However, Type K Thermocouple Extension Wire may not be physically exposed to that high temperature. A Stranded Thermocouple Wire can be used as an extension wire but an extension wire cannot be used in a Flexible Thermocouple Wire as a sensing point. The usable length of these wires differs based on numerous factors.


  • Thermocouple Wire
Code Wires component of the thermocouple
+Positive leg -Negative leg
N Ni-cr-si (NP) Ni-si-magnesium (NN)
K Ni-Cr (KP) Ni-Al(Si) (KN)
E Ni-Cr (EP) Cu-Ni<constantan> (EN)
J Iron (JP) Cu-Ni<constantan> (JN)
T Copper (TP) Cu-Ni<constantan> (TN)

  • ​Standards
ASTM ANSI IEC DIN BS NF JIS GOST
(American Society for Testing and Materials) E 230 (American National Standard Institute) MC 96.1 (European Standard by the International Electrotechnical Commission 584)-1/2/3 (Deutsche Industrie Normen) EN 60584 -1/2 (British Standards) 4937.1041, EN 60584 - 1/2 (Norme Française) EN 60584 -1/2 - NFC 42323 - NFC 42324 (Japanese Industrial Standards) C 1602 - C 1610 (Unification of the Russian Specifications) 3044

Detailed Parameter of thermocouple wire

Working Temperature Range

Diameter/mm Long time Working temperature /ºC Short period Working temperature /ºC
0.3 700 800
0.5 800 900
0.8,1.0 900 1000
1.2,1.6 1000 1100
2.0,2.5 1100 1200
3.2 1200 1300

Thermocouple No. indexing Compensation wire type Usag Classification Measuring junction temperature / ℃ standard EMF value/μV Precision grade General grade
Tolerance μV Thermal EMF range μV Tolerance μV Thermal EMF range μV
SorR SC or RC G 100 646 ±30 616~676 ±60 586~706
H 100 646 - - ±60 586~706
200 1 1441 - - 1.381~1 501
K KX,KCA G -25 -968 ±40 -924~-1 012 ±80 -880~-1 056
or KCB 100 4 096 4 052~4 140 4 008~4 184
H -25 -968 ±40 -924~-1 012 ±88 -880~-1 056
100 4 096 4 052~4 140 4 008~4 184
200 8 138 8 094~8 182 8 050~8 226
N NX or NC G -25 -646 ±43 -603~-689 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
H -25 -646 ±43 -603~-690 ±86 -560~-732
100 2 774 2 731~2 817 2 688~2 860
200 5 913 5 870~5 956 5 827~5 999
E EX G -25 -1 432 ±81 -1 351~-1 513 ±138 -1 294~-1 570
100 6 319 6 238~ 6400 6 181~6 457
H -25 -1 432 ±81 -1 351~- 1513 ±138 -1 294~-1 570
100 6 319 6 238~6 400 6 181~6 457
200 13 421 13 340~13 502 13 283~13 559
J JX G -25 -1 239 ±62 -1 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
H -25 -1 239 ±62 - 177~-1 301 ±123 -1 116~-1 362
100 5 269 5 207~5 331 5 146~5 392
200 10 779 10 717~10 841 10 656~10 902
T TX G -25 -940 ±30 -910~-970 ±60 -850~-1 000
100 4 279 4 249~4 309 4 189~4 339
H -25 -940 ±48 -892~-988 ±90 -850~-1 030
100 4 279 4231~4 327 4 189~4 369
200



Size range



Wire: 0.12 to 8.0 mm.

  • Type N Accuracy (whichever is greater):
  • Maximum continuous operating temperature: up to 2,300F (1,260C)

  • Short term use: 2,336F (1,280C)

  • Thermocouple grade wire, -454 to 2300F (-270 to 1,260C)

  • Extension wire, 32 to 392F (0 to 200C)

Send your message to this supplier
Send Now

Thermocouple Type K Extension Cable For Temperature Compensation

Ask Latest Price
Brand Name :
DLX
Model Number :
Type k Thermocouple extension wire
Certification :
CE,ROHS
Place of Origin :
China
MOQ :
5
Payment Terms :
L/C, T/T, Western Union, MoneyGram
Contact Supplier
Thermocouple Type K Extension Cable For Temperature Compensation
Thermocouple Type K Extension Cable For Temperature Compensation
Thermocouple Type K Extension Cable For Temperature Compensation
Thermocouple Type K Extension Cable For Temperature Compensation

Changzhou DLX Alloy Co., Ltd.

Verified Supplier
5 Years
jiangsu, changzhou
Since 2016
Business Type :
Manufacturer, Seller
Total Annual :
1000000-120000000+
Employee Number :
100~150
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement