2020 Latest Walk Through Infrared Thermal Temperature Detector Door For Human Body Temperature Detecting
Description:
1. Accuracy: ± 0.1 ° C.
2. Response time: 1 second, passing rate is about 50-60 people / min.
3. Temperature measurement detection area: the imported medical double probe technology is adopted, which is the first in the industry to install one probe at the left rear and one probe at the inner inclined edge of the right front door, fully covering the area range of 0.5m * 0.5m at the right front of the door frame and 0.5m * 0.5m at the left rear of the door body. Through the acceptable cost of enterprises and institutions, the natural traffic speed close to infrared thermal imaging can be realized.
4. Alarm mode: voice alarm, real-time display of body temperature.
5. Intelligent statistics: the intelligent passenger flow and alarm counting function can automatically count the number of
people passing and the number of alarms
6. The 7-inch screen displays real-time body temperature and records the number of people tested.
7. Only temperature detect, without metal detector
Specification: | ||
Infrared Thermal Imaging | Power Supply | USB supply 5V(+-10%) |
Power Consumption | regular work < 0.85W | |
baffle opened for calibration < 1.6W | ||
Sensor type | Vanadium oxide uncooled infrared focal plane detector | |
Image resolution | 256*192 | |
Field Angle | Level:56° x vertical:42° | |
Pixel Size | 12μm | |
NETD | ≤60mk(<50mk@25℃ F#1.0 25Hz) | |
Image capture frequency | <25Hz | |
Lens focal length | 3.2mm | |
Focus Mode | Non-thermalized prime lens | |
lens aperture | F#1.1 | |
gain control | high-gain mode | |
Noise Reduction | 2D Noise Reduction | |
Visible Light | Sensor type | AR0230/1080P |
Pixel | 2 million | |
Field Angle | 62° | |
image resolution | 1920*1080 | |
noise reduction | 2D noise reduction | |
SNR | Max 41dB | |
white balance | automatic white balance | |
Lens focal length | 4.35mm+/-5% | |
Optical lens aperture | 2.0+/-5% | |
Image format | jpg | |
Temperature measurement parameters | Optimum operating temperature | 25~32°C |
Biological temperature range | 32~42°C | |
environmental requirement | Indoor, No wind | |
Accuracy | ± 0.1°C | |
Region | Full-screen multi-face automatic tracking | |
Optimum range | 2.5m | |
Anomaly Alarm | alarm threshold setting of the highest and lowest temperature | |
Operating Humidity | < 90% | |
Door Frame | Protection Grade | A |
Dimension | 2200(H)*800(W)*660(D)mm | |
Tunnel Size | 2000(H)*700(W)mm | |
Voltage | 110-220V 50HZ | |
Ballhead Camera | Material | Aluminium Alloy |
Dimension | Bottom Diameter 145*120(H)*Facial Diameter90 mm | |
Screen | size | 260*179*25.5mm |
Applications:
Can be widely used in Shopping malls, hotels, workplaces, subways, stations, hospitals and other public places