Hot sell multiparameter patient monitor equipment medical monitor vital signs monitor
Battery
Battery type | rechargeable li-ion battery 12V/2300mAH |
Recharge time | ≥4 hour |
Use time | ≥120 minute |
Power
Supply power | AC 220V±10% 50/60Hz±2% |
power | 80VA |
Fuse specifications and models, rating | T2.5AL/250V Φ5×20 |
Display mode | LCD display |
Alarm mode | Audible and visual |
Network connection | Can be expanded |
ECG
Lead | Standard Three leads | R,L,N, lead mode :Ⅰ,Ⅱ,Ⅲ | |
Standard Five leads | R,L,F,N,C, Lead mode :Ⅰ,Ⅱ,Ⅲ,aVR,aVL,aVF,V; | ||
Sensitivity | 2.5mm/mV,5mm/mV,10mm/mV,20mm/mV,erro≤±3% | ||
Scan speed | 12.5,25,50mm/s three level,erro ≤±10% | ||
Inner voice | <30μVP-P | ||
input impedance | ≥5MΩ | ||
input loop current | ≤0.1μA | ||
endure electrode polarizing voltage | ±300mV | ||
Frequency property | diagnosis mode 0.05~130HZ monitoring mode 0.5~40HZ operating 1~20HZ | ||
CMRR | Diagnosis mode ≥90dB Monitoring mode ≥100dB Operating mode ≥100dB | ||
HR measurement range | Adult 15~300bpm Neonate /pediatrics 15~350bpm | ||
HR accuracy | ±2% | ||
alarm range | 0~301bpm, upper and lower limit can be adjusted continuously | ||
alarm indicator | Audial and visual alarm | ||
protection | Isolated immunity voltage 4000V, Immunity of electronic surgical Anti-defibrillation | ||
protection and recovery for defibrillation effect | In the monitor and the surgical model ,ECG waveforms recovery to baseline in 5S. | ||
Electrode polarization recovery time after the fibrillation | In the monitor and the surgical mode ,ECG waveforms recovered to baseline in 10S. | ||
measurement mode | Diagnosis mode,monitoring mode,operation mode | ||
pace marker pulse detection and suppressing | width | ±2mV~±700mV | |
broadband | 0.1ms~2ms | ||
risetime | 10μs~100μs | ||
ECG signal input range | -8.0mV~+8.0mV | ||
HR sensitivity | >200μV |
NIBP
measurement range | adult | systolic pressure | 40~270mmHg |
diastolic pressure | 10~215mmHg | ||
mean pressure | 20~235mmHg | ||
pediatrics | systolic pressure | 40~200mmHg | |
diastolic pressure | 10~150mmHg | ||
mean pressure | 20~165mmHg | ||
neonate | systolic pressure | 40~135mmHg | |
diastolic pressure | 10~100mmHg | ||
mean pressure | 20~110mmHg | ||
measurement precision | ±5mmHg | ||
display unit | mmHg,Kpa | ||
alarm range | Systolic pressure | 0~301mmHg,upper and lower limit can be adjusted continuously | |
diastolic pressure | 0~301mmHg,upper and lower limit can be adjusted continuously | ||
alarm indicator | Audial and visual | ||
measurement mode | adult | Single , cycle, speedy | |
pediatrics | Single, cycle,speedy | ||
neonate | single,cycle | ||
static pressure range | 0~300mmHg | ||
static pressure precision | ±3mmHg | ||
pulse measurement range | 40~240bpm | ||
protection adult | Dual hardware,software overpressure protection 300mmHg | ||
Period measurement time interval (minute) | 1,3,5,10,15,30,60,90,120,180,240,480 |
Sp02
SpO2 measurement range precision | 0~100% ±2%(70~100% ) |
PR measurement range precision | 20~300 bpm ±2% |
Alarm range | 0~100%,upper and lower limit can be adjusted continuously |
Alarm indicator | Audial and visual alarm |
RESP
Measurement range | adult 7~120 bpm pediatric /neonate 7~150 bpm |
precision | ±2bpm |
impedance test range | 0.3~3Ω |
base line impedance range | 200~4000Ω(50~120kHz pump-frequency) |
apnea alarm time | 10~40s |
alarm range | 0~121bpm, up and down limit can be adjusted continuously |
alarm indicator | Audial and visual alarm |
Packing:
Shipping:
A. If the quantity of the order is not very big, we could send to you by express delivery. Such as TNT, UPS, DHL, Fedex.
B. If the order is so big, we will advise you use Air Shipping or Sea Shipping through your nominated forwarder FOB China Port.
C. Freight collect if bulk shipment.
Certificate:
Welcome To STATEMED!
Professional supplier,your best choice!
Reasonal price,high quality!