7 inch LCD Display Mobile Multi Parameter Patient Monitor CE Proved
Basic Function
1. 7" narrow screen TFT true color high definition LCD, Small volume, light weight.
2. Real time display the waveform of ECG, SPO2, RESP, Meanwhile, display the digital data of HR/PR, Dual TEMP, RESP, SP02, NIBP, etc, ETCO2 is optional
3. Three monitoring mode: Monitor, Operation, Diagnosis
4. Blood pressure measurement has three modes: Manual, Cycle, and Fast measurement
5. Freezing and Starage
6. Display the latest 400 NIBP data
7. Store 96 hours trend chart
8. Sound & light alarm system
9. AC-DC power
10. Li battery, working time is more than 4 hours
11. Two modes for choice: LCD type & LED type
12. USB data storage and export
13. SIM card signal transmission.
Technical specifications
Product model | STT-601A |
Dimension of appearance | 165mm×160mm×250mm(LXWXH) |
Dimension of packing | 283mm×193mm×288mm(LXWXH) |
Weight | NW:2.8kg(including accessory 0.7kg ) |
Display screen | 7”LCD |
Power | 90VA |
Fuse specification | T2.0AL/250V |
Type of battery | Lithium battery 11.1V/2.2Ah |
Recharge time(up to the time of 90% electric quantity) | ≥4 (hours) |
Work time | 3 hours |
Motoring of physiological parameters | ECG,HR,BP,SPO2,PR,Dual-TEMP,RESP,CO2 EtCO2 is optional |
Display interface | Standard interface,trend coexistence interface,oxyCRG interface |
Standard of configuration | European standard of five lead ECG cable,adult cuff,adult blood oxygen probe,body surface probe,Coelom probe |
Functions and features |
|
Extended function | 12v DC power supply ,internet access |
(Sp02)
SpO2 measurement range | 0~100% |
alarm range | not less than 35~100% |
alarm indicator | audio and visual , SPO2 parameter |
PR measurement range | 25~255 bpm |
data up-date cycle | 1s |
(RESP)
measurement range | 0~100time/min |
Test precision | ±1time/min |
alarm range | Not less than 0~100time/min |
alarm indicator | audio and visual , RESP |
TEMP
measurement range | not less than 20.0~50.0℃ |
Test precision | ≤±0.2℃ less than ±0.2℃ |
alarm range | not less than up limit and down |
alarm indicator | audio and visual alarm, TEMP |
minimum measurement time | ≤100sless than 100s |
CO2 (Option)
collection method | side-streaming |
collection gas flow rate and range | 50mL/min±10% |
CO2 measure range | 0~10%(@BTPS) |
CO2 test precision | error less than +/- 2mmHg,when |
alarm range | not less than up and down |
alarm resolution ratio | 1mmHg |
resolution ratio | 0.1mmHg(0 - 69mmHg),0.25mmHg(70-150mmHg) |
initialization time | CO2 waveform is displayed in 10s,all the parameters will display within 6 minutes under 23 ℃ |
compensation | this monitor automatic give pressure compensation |
system total response time | less than 4s |
Measurement drifting of accuracy | ≤2mmHg less than 2mmHg |
Alarm
alarm level | high, medium , low |
alarm type | technical alarm, physiology alarm |
alarm method | audio, indicator, prompt message, parameter flicker |
alarm delay | ≤0.5s less than 0.5s |
sound pressure | 45~85dB |
Recorder
method | thermosensitive dot matrix |
record method | thermosensitive paper |
recorder paper width | 57mm |
paper specification | diameter 40mm/roll
|
record content | waveform, words |
record tracking | 2 channel |
speed | 25mm/s |