API High Pressure Choke Manifold For Surface Well Testing Operation
The Choke manifold is a 3-1/16'' 10,000Psi system. The assembly comprises (5) 3-1/16'' Cameron type gate valves, (1) adjustable choke and (1) fixed choke arranged as a square manifold with a central choke by-pass line. The two sets of fixed choke are available. The inlet block and outlet block have additional blind flanges c/s (2) 1/2" NPT tapings that may be used for connecting gauges or instrumentation. All wetted components comply with NACE(MR-01-75), suitable for sour service.
Benefits of Well Testing Choke Manifold
Technical Parameter of Choke Manifold
service: | Sour Gas | |||||
Material class: | EE-NL(Tungsten Carbide Hardfaced) | |||||
Rated. working pressure: | 10,000Psi | |||||
Hydraulic test pressure: | 15,000Psi | |||||
Maximum working temperature: | API P to U(-20 ~ 250 ℉) | |||||
Valves: | 3-1/16'' manually gate valve | |||||
(4) 3-1/16'' gate valves | ||||||
(1) 3-1/16'' gate valves on by-pass line | ||||||
Adjustable choke: | 2'' maximum opening | |||||
Fixed choke: | 2'' choke seat, c/w one standard set of beans: | |||||
4/64'', 8/64'', 12/64'', 16/64'', 20/64'', 24/64'', | ||||||
28/64'',32/64'', 36/64'', 40/64'', 44/64'', 48/64'', | ||||||
52/64'',56/64'',64/64'', 72/64'', 80/64'', 88/64'', | ||||||
96/64'', 104/64'',112/64'', 120/64'', 128/64'' | ||||||
Inlet connection: | 3'' Fig 1502 female | |||||
(or 3-1/16" 10K BX154 Flange connection) | ||||||
Outlet connection: | 3'' Fig 1502 male | |||||
(or 3-1/16" 10K BX154 Flange connection) | ||||||
Others | Mounted on a heavy duty oilfield skid c/w slings and there is tool box mounted on the skid | |||||
Standards | NACE MR0175 API 6A, ANSI B31.3 PSL-3,EE,P+U, NO inlays in RTJ’S |