1. Main Features and Functions
(1) Display: LED digital meter can display voltage, capacity and time.
(2) Control pattern: keyboard set the whole battery set protective voltage, current, capacity, discharging time.
(3) Automatic stop: It can automatically stop discharging meet following conditions: testing time out, testing capacity out and protective voltage out.
(4) Protection: When high temperature, opposing connection, battery cable disconnection occur, load bank will give alarm sound and automatically cut off the load.
(5) The parameter set in last time could be saved automatically to avoid the same work for the same battery model.
2. Technical Parameters Sheet
Model | DC360-100 |
Battery Nominal Voltage | DC360V/220V/110V |
Discharging Voltage | For 360V Discharge Voltage: 280-490V, within 360V±10% guarantee the highest current 150A, can discharge for long time, changing according to Ohm's Law. For 220V Discharge Voltage: 96-275V, within 220V±10% guarantee the highest current 150A, can discharge for long time, changing according to Ohm's Law. For 110V Discharge Voltage: 48-137V, within 110V±10% guarantee the highest current 100A, can discharge for long time, changing according to Ohm's Law. |
Protective Voltage | 1-490V |
Discharging Current | 1-100A |
Discharging Time | 1 minute-99 hours and 59 minutes |
Discharging Capacity | 1-9999Ah |
Group Voltage Tolerance | ±1% |
Current Tolerance | ±1% |
Constant-current Discharge Control | ±(0.3%+0.2A) |
Power Supply | AC220V,50Hz, single phase |
Cooling | Forced air cooling |
Environment temperature | -10℃ - +40℃ |
Weight(kg) | About 70kg |