with DC immunity current transformer(specifications) | |
Exterior Material | PBT Resin UL flame retardant rating 94-V0 |
Interior Insulation | Epoxy Encapsulated |
Isolation Voltage | 2500 Vrms for 1 minute |
Dielectric Resistance | 1000 M Ohms @ 500 Vdc |
Surge Withstand | 5000V(1.2/50μs standard shock wave)optional |
Rated Load Resistance | 100K Ohms |
Operating Temperature | -25 to +55℃,-40 to +85℃optional |
Frequency | 50 to 400 Hz |
Accuracy Class | defined in IEC 60044-2 Part 2 Voltage Transformers Class 0.1 |
Certification | RoHS Compliant |
with DC immunity current transformer(features) |
Low cost Small size |
More than 10 standard sizes Terminal: PCB Mounted or Lead |
High accuracy,wide linear range,good consistency |
with DC immunity current transformer(applications) |
For applications that require exceptional accuracy with minimal phase angle error |
Applications would include watt-hour metre ect. electric energy measurement device Electronic watthour meters according to IEC 62053 -21, -23 must have a tolerance to DC current |
Part | IN | Imax | Iref | Accu- | Rcu [Ω] | Rb [Ω] | Outline Dimen- | P/L | |
GWTAD014-5(20)A | 5 | 20 | 15 | 0.2 | < 3% | 120±10% | 12.5 | ID-OD-H | L |
GWTAD014- | 10 | 40 | 30 | 120±10% | |||||
GWTAD016- | 10 | 60 | 45 | 110±10% | ID-OD-H | ||||
GWTAD016- | 20 | 80 | 60 | 110±10% | |||||
GWTAD020- | 20 | 100 | 75 | 90±10% | ID-OD-H | ||||
GWTAD020- | 20 | 120 | 85 | 90±10% | |||||
GWTAD22D- | 10 | 60 | 45 | 110±10% | ID-L-W-H | P/L | |||
GWTAD22D- | 20 | 80 | 60 | 110±10% | |||||
GWTAD22E- | 20 | 100 | 75 | 90±10% | ID-L-W-H | ||||
GWTAD22K-20(80)A/8mA | 5 | 80 | 60 | 105±10% | ID-OD-H | L |