Temperature Type Battery Short Circuit Tester
1.Battery Short Circuit Test EquipmentTest Purpose
Remote integral battery large current short circuit test machine is designed to complies with standards at theinternal resistance far less than 5mΩ to achieve large short-circuit current.
2.Battery Short Circuit Test Equipment Introduction
Battery large current short-circuit machine is designed to comply with standard; According to the short-circuit test requirement, the short-circuit must be less than 5 mΩ to achieve maximum current; In additional, a load-bearing capacity must be designed in electrical system for short-circuit system. Thus, Bell R&D team selects industrial DC magnetic contact with full copper terminal and internal copper current conduction,and internal active bead axial fan is mounted to cool to ensure the test system more safer and reduce the test machine power consumption and enable the test data in accuracy.
Test judgment standards: no flame or explosion after battery short-circuit test.
3. Battery Short Circuit Test Equipment Standard Compliance
GB/T 18332.2-2009 Nickel-metal hydride batteries of electric road vehicles
GB/Z 18333.1-2001 Lithium-ion batteries for electric road vehicles
GB/Z 18333.2-2001 Zinc-air batteries for electric road vehicles
QC/T 741-2006 Ultra capacitors for Vehicles
QC/T 742-2006 Lead-acid batteries for electric vehicles
QC/T 743-2006 Lithium-ion batteries for electric vehicles
QC/T 744-2006 Nickle-metal hydride batteries for electric vehicles
Vehicles battery related international standard (ISO/IEC/SAE/JEVA/CEN etc.) International Standard Association and 863 plan electric vehicles major projects related test specifications
QB/T 2947.3-2008 Electric bicycles-cell or battery and chargers Part 3:Li-ion batteries and chargers
DB12/T246-2005 Lithium batteries for electrical bicycles test specification
GB 19521.11-2005 Safety code for inspection of hazardous properties for dangerous goods of lithium batteries
4. Battery Short Circuit Test EquipmentTechnical Parameters
Model | BE-1000A | BE-2000A | BE-3000A | BE-5000A | BE-10000A | |||||
Max. Operating Current(A) | 1000 | 2000 | 3000 | 5000 | 10000 | |||||
Rated Insulation Voltage(V) | 1000 | 1000 | 1000 | 1000 | 1000 | |||||
Internal Resistance System | ≤100mΩ | ≤5mΩ | ||||||||
Additional Function | Voltage, current, temperature acquisition, video monitoring system, fire fighting system,anti-explosive system, smoke exhaust system, smoke filtering system . | |||||||||
Testing Environment | Ambient Temperature | |||||||||
Operating Method | Long distance wireless control | |||||||||
Anti- explosive Cabinet (mm) | 500X500X500MM、800X800X800MM、1000X1000X1000MM available to customize | |||||||||
External Dimension | according actual design | |||||||||
Configuration | Voltage | 0—10V,0--100V,0—1000V | ||||||||
Temp. Sampling Range | -200℃ ~ 1200℃ | |||||||||
Voltage Temp. Accuracy | ±1%FS | |||||||||
Voltage Resolution | 1mV | |||||||||
Temperature Resolution | 0.1℃ | |||||||||
Main Technical Parameters | Max. Instantaneous Current | 1500A | 2500A | 3500A | 6000A | 12000A | ||||
Response Time | ≤5μs | |||||||||
Short residence time | 0~999S,time and state controllable | |||||||||
Current Accuracy | ±1%FSR,Resolution :0.1A | |||||||||
Max. Specimen Dimension | 1000X1000X1000MM | |||||||||
Resistance Material | Copper | |||||||||
Acting Time | Pick-up time/ release time ,less than 30ms | |||||||||
Driving Method | Electric | Pneumatic | Electric | |||||||
Structure | Cabinets | vertical or horizontal structure separate from control part | ||||||||
Communication | Adopt R232,485 communication interface,ensure remote acquisition stability and real time, with anti-explosive function . | |||||||||
Fixture | Connector or customize clamp according to samples provided | |||||||||
Data Acquisition Module | Independent remote capture, various voltage,temperature, current capture channel, ensure data accuracy. | |||||||||
Standard channel quantity | 2channels ,4channels , 8channels ,various data acquisition system , optional | |||||||||
Camera Monitoring System | Test zone installed with high definition camera monitoring system in remote control with explosion-proof (optional). | |||||||||
Standard Configuration | Short-circuit host, data acquisition system,explosion-proof system (camera monitoring,fire-extinguish system, smoke exhaust system optional) | |||||||||
Safety Protection | Electric leakage, over-temp.,over-voltage, over-current, fault alarm, smoke alarm. | |||||||||
Testing Fixture | Customize according to actual working condition | |||||||||
Power Source | AC220V 50HZ | |||||||||
Working Environment | 0℃~45℃ |