-5℃ Industrial Low Temperature Glycol Chilling Unit For Dairy Processing Line
1.The unit is applicable to various place needing lowtemperature cold source, such as pharmaceutical, chemical, metallurgy, electronics, food and other industries;
2.-5℃,-10℃,-15℃,-25℃......-80℃ outlet water temperature can be achieved;
3.Host international advanced semi-hermetic screw compressor, motors, compressors integration, no seal leakage of concern;
4.Unit compact, small footprint, saving floor space;
5.Microcomputer control unit, simple operation.
Product | Screw Water cooled glycol chiller | |||
Model | MG-100WSL | |||
Power supply | 3PH-220V380V/415V/460-50HZ/60HZ | |||
Chilled water flow(m3/h) | 45 | |||
Total power consumption (kW) | 65 | |||
Cooling capacity | KW | 206.2 | ||
kCal/hr | 177330 | |||
Compressor | Type | Semi-hermetic screw | ||
Quantity | 1 | |||
Start method | Y | |||
Energy control | 0-25%-50%-75%-100%( start @ 25%) | |||
Condenser | Type | Shell and tube | ||
Cooling water flow(m3/h) | 68 | |||
Quantity | 1 | |||
Refrigerant | Type | R22/R407c/R134a | ||
Expansion valve | Type | Thermostatic expansion valve | ||
Evaporator | Type | Shell and tube | ||
Inlet/Outlet pipe dimension | PT5" | |||
Safety protection | Compressor over temperature,over current,high and low pressure,Phase sequence,phase-missing | |||
Dimension | L*W*H(mm) | 3200*900*1880mm | ||
Machine weight | kg | 1920 |
Feature:
1.Water cooled water chiller adopt the World Name Brand Compressor:Bitzer, Hanbell;
2.Control system of water chiller has a capacity of 4, energy regulation: [0-25-50-75-100% ].Can be the basis of changes in load-conditioning Unit from the transport to stop and open and effective energy saving;
3.Run-time, computer-controlled cooling system of water chiller will be based on changes in thermal load to change the unit of energy output;
4.Stainless steel heat exchange, with automatic watering system, which has convenient and quick cleaning maintenance;
5.Highly effective live threshold energy quantity control, realizes the graduation or stepless energy control. The balanced design, revolves ultra static steady;
6.Moves the parts to process strictly ,wipes the row of gas oil counterbalance design specially, the maintence cycle is long ,the trouble-free moves above for 40000 hours.
Glycol chilling unit details:
Glycol chilling system design:
Payment term:
T/T: 50% Down payment, the balance before shipment, or you also can show us if any special required.
L/C,D/P,DDU and etc.
Looking forward long and good cooperation from all over the world! MGREENBELT will give our agent price and good service.