Application
No. | Parameter | Performance Indicators | Unit | ||
03 | 02 | 01 | |||
1 | Bias | ≤6 | ≤6 | ≤6 | mg |
2 | Scale Factor | 1.0~1.4 | 1.0~1.4 | 1.0~1.4 | mA/g |
3 | Second-order Nonlinearity | ≤30 | ≤40 | ≤50 | μg/g 2 |
4 | Bias Temp Coefficient | ≤30 | ≤40 | ≤50 | Μg/℃ |
5 | Scale Factor Temp Coefficient | ≤60 | ≤70 | ≤80 | Ppm/℃ |
6 | Bias Repeatability | ≤50(one month) | ≤50(3~7 days) | ≤50(one day) | μg |
7 | Scale Factor Repeatability | ≤50(one month) | ≤50(3~7 days) | ≤50(one day) | ppm |
8 | Second-order Nonlinearity Repeatability | ≤30(one month) | ≤30(3~7 days) | ≤30(one day) | μg/g 2 |
9 | Natural Frequency | ≤800 | ≤800 | ≤800 | Hz |
10 | Acceleration Range | ≥20 | ≥20 | ≥20 | g |
11 | Vibration | 8 | 8 | 8 | grms |
12 | Shock | 120g,4.5ms,1/2sin | 120g,4.5ms,1/2sin | 120g,4.5ms,1/2sin | g, ms |
13 | Operating Temp | -45~+80 | -45~+80 | -45~+80 | ℃ |
14 | Weight | ≤40 | ≤40 | ≤40 | g |
15 | Resolution | ≤5×10 -5 | ≤5×10-5 | ≤5×10 -5 | g |
16 | Operating Voltage | ±12~ ± 15 | ±12~± 15 | ±12~± 15 | v |
ER-I/E is applied in extensive measurement range system and acceleration test
system.
Features: High-precision and small volume.
Installation Dimensions