Specifications
Model Number :
TA2100
Name :
Fluke Multifunction Calibrator
Features :
wide range, multi value and high precision
Application :
Clamp ammeters
Origin :
China
Model :
TA2100
Accuracy :
0.02% ; 0.05%
Place of Origin :
China
Brand Name :
TUNKIA
MOQ :
negotiation
Price :
negotiation
Packaging Details :
Standard
Payment Terms :
negotiation
Description
TA2100 AC Power Calibrator

Introduction

  • TA2100 a wide-range, multi-value and high-precision calibrator, can accurately output ultra-precision AC voltage, current and power, with two specifications of 0.02% and 0.05%.

  • It is suitable for calibrating AC power analyzers, AC power meters, AC voltmeters, and AC ammeters.

Features

  • Electrical Parameters Output: Voltage is up to 1100 V, current is up to 110 A at a frequency of 45 Hz ~ 70 Hz (400 Hz optional).

  • AC power output: calibrate the active power, reactive power, apparent power and power factor of the meter under test.

  • Value Adjustment Method: Fixed-point, rotary encoder, step and potentiometer (option).

  • Output Switch: The output can be turned on/off arbitrarily by one-touch operation.

  • Statistical analysis function: Automatically record the maximum and minimum values of electricity, calculate the average value and standard deviation, and analyze the stability.

  • High reliability of the whole machine: with overload protection, voltage short circuit protection, current open circuit protection, overheating protection, etc.

  • Excellent Human-Computer Interaction: Large LCD touch screen display, touch and button operation modes, easy for users to measure manually.

Specification

AC Voltage Output ACV

Range Resolution Stability (%/min) Accuracy Max. Load Current (mA) Distortion (%)
0.05% 0.02% 0.05% 0.02%
3 V 10 μV 0.01 0.005 300 + 200 120 + 80 600 < 0.5
10 V 100 μV 0.01 0.005 300 + 200 120 + 80 600 < 0.5
30 V 100 μV 0.01 0.005 300 + 200 120 + 80 600 < 0.5
100 V 1 mV 0.01 0.005 300 + 200 120 + 80 500 < 0.5
300 V 1 mV 0.01 0.005 300 + 200 120 + 80 150 < 0.5
600 V 1 mV 0.01 0.005 300 + 200 120 + 80 80 < 0.5
1000 V 10 mV 0.01 0.005 300 + 200 120 + 80 50 < 0.5
  • Output Range: 0.3 V ~ 1100 V; Resolution: 0.001 %*RG;

  • Short circuit protection, overload protection

AC Current Output ACI

Range Resolution Stability (%/min) Accuracy Max. Load Voltage (mA) Distortion (%)
0.05% 0.02% 0.05% 0.02%
3 mA 10 nA 0.01 0.005 300 + 200 120 + 80 60 < 0.5
10 mA 100 nA 0.01 0.005 300 + 200 120 + 80 60 < 0.5
30 mA 100 nA 0.01 0.005 300 + 200 120 + 80 60 < 0.5
100 mA 1 μA 0.01 0.005 300 + 200 120 + 80 60 < 0.5
300 mA 1 μA 0.01 0.005 300 + 200 120 + 80 60 < 0.5
1 A 10 μA 0.01 0.005 300 + 200 120 + 80 60 < 0.5
3 A 10 μA 0.01 0.005 300 + 200 120 + 80 30 < 0.5
10 A 100 μA 0.01 0.005 300 + 200 120 + 80 6 < 0.5
30 A 100 μA 0.01 0.005 300 + 200 120 + 80 3 < 0.5
100 A 1 mA 0.01 0.005 300 + 200 120 + 80 1.5 < 0.5
  • Output Range: 0.3 mA ~ 110 A; Resolution: 0.001 %*RG;

  • Open circuit protection, overload protection

AC Small Voltage Output

Range Resolution Stability (%/min) Accuracy Distortion (%)
0.05% 0.02% 0.05% 0.02%
5 mV 10 nV 0.02 0.02 300 + 2 120 + 1 < 0.5
20 mV 100 nV 0.01 0.01 300 + 4 120 + 2 < 0.5
50 mV 100 nV 0.01 0.005 300 + 10 120 + 5 < 0.5
200 mV 1 μV 0.01 0.005 300 + 40 120 + 15 < 0.5
500 mV 1 μV 0.01 0.005 300 + 100 120 + 40 < 0.5
2 V 10 μV 0.01 0.005 300 + 400 120 + 150 < 0.5
5 V 10 μV 0.01 0.005 300 + 1000 120 + 400 < 0.5
  • Output Range: 0.5 mV ~ 6 V; Resolution: 0.001 %*RG;

  • Short circuit protection, overload protection; This output is suitable for the small signal input of the sensor of the power analyzer.

AC Power Output

Type Stability (%/min) Accuracy (k = 2) %*FS
0.05% 0.02% 0.05% 0.02%
Active Power 0.01 0.005 0.05 0.02
Reactive Power 0.01 0.01 0.1 0.05
Apparent Power 0.02 0.01 0.05 0.02
Power Factor 0.02 0.01 0.1 0.02

  • Output Range of AC Power: Combination of AC voltage range and AC current range.

  • Range of Power Factor: -1.0000…0.0000…+1.0000

  • Active Power (|cosφ| ≥0.5), Reactive Power (|sinφ| ≥0.5)

Frequency and Phase

  • Range of Frequency: 45.000 0 Hz ~ 70.000 0 Hz

  • Resolution of Frequency: 0.000 1 Hz

  • Accuracy of Frequency: 0.005 Hz

  • Range of Phase: 0.000 ° ~ 359.999 °

  • Resolution of Phase: 0.001 °

  • Accuracy of Phase: 0.05 ° (0.05%), 0.02 ° (0.02%)

Send your message to this supplier
Send Now

AC Electrical Power Calibrator TA2100 Multi Value High Precision

Ask Latest Price
Model Number :
TA2100
Name :
Fluke Multifunction Calibrator
Features :
wide range, multi value and high precision
Application :
Clamp ammeters
Origin :
China
Model :
TA2100
Contact Supplier
AC Electrical Power Calibrator TA2100 Multi Value High Precision

Tunkia Co., Ltd.

Verified Supplier
2 Years
Since 1998
Business Type :
Manufacturer, Seller, Other
Main Products :
Employee Number :
300~500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement