TD1050A Calibration Device for Clamp Meter

Introduction

  • TD1050A, a calibration device for clamp ammeters. The optional accuracy are 0.02% and 0.05%.

  • The device calibrates the AC/DC clamp ammeters by single coil with high accuracy and easy traceability, and has the functions of AC/DC current output, resistance simulation, frequency/phase adjustment, power detection.

  • Meet the requirements of JJF 1075-2015 Calibration Specification for Clamp Ammeter. (Tunkia is involved in drafting)

Features

  • Calibrate AC/DC clamp ammeters by single coil: The AC/DC current source connect to a single coil semi-circular copper ring with a diameter of 1m, can directly output AC/DC high current up to 2200 A (or 1100 A). Suitable for calibrating AC/DC clamp ammeters with high accuracy.

  • Place the clamp meter in the center of the copper ring when calibrating. The diameter of the copper bar in the center position is smaller than the other positions, which is convenient for the access of small size clamp meters.

  • Easy to open the copper ring, and thread a standard current transformer or I-V converter into the ring for calibrating the device itself regularly.

  • Reserved terminals for high current, to provide current for the calibration of DC shunts.

  • Value Adjustment Method: Fixed-point, rotary encoder, and step.

  • Frequency and Phase (Option): The AC output frequency and the phase between voltage and current is variable.

  • Power Output (Option): Test DC power, active power, reactive power, apparent power and power factor.

  • Proprietary Software (Option): Support the calibration of the checked ammeters by semi-automatic or full-automatic, data management and report export.

Application

Calibrated Types

Accuracy of Calibrated Device

0.02% Calibrator

0.05% Calibrator

AC/DC Ammeters

0.1 and below

0.2 and below

AC/DC Voltmeters

0.1 and below

0.2 and below

DC Resistance

0.2 and below

0.2 and below

AC/DC Power

0.2 and below

0.5 and below

DC Shunts

0.1 and below

0.2 and below

Specification

AC Voltage Output

Range Stability (%/min)

Accuracy (k = 2)

(ppm*RD + ppm*RG)①

Max. Load

Current (mA)

0.02% 0.05% 0.02% 0.05%
10 V 0.005 0.01 120 + 80 300 + 200 800
30 V 0.005 0.01 120 + 80 300 + 200 700
100 V 0.005 0.01 120 + 80 300 + 200 200
300 V 0.005 0.01 120 + 80 300 + 200 70
750 V 0.005 0.01 120 + 80 300 + 200 30
Remarks: ①: RD is the reading,RG is the range
  • Output Range of Voltage: 1 V ~ 825 V

  • Display: 6 digits

  • Resolution: 0.002 %*RG

  • Distortion: <0.5 %

  • Protection: Short-circuit protection, overload protection, overheating protection.

AC Current Output

Model Range Resolution Stability (%/min)

Accuracy (k = 2)

(ppm*RD + ppm*RG)

Max. Load

Voltage (V)

0.02% 0.05% 0.02% 0.05%
Small current loop 100 mA 1 μA 0.01 0.01 120 + 80 300 + 200 10
300 mA 1 μA 0.01 0.01 120 + 80 300 + 200 10
1 A 10 μA 0.01 0.01 120 + 80 300 + 200 10
3 A 10 μA 0.01 0.01 120 + 80 300 + 200 10
10 A 100 μA 0.005 0.01 120 + 80 300 + 200 10
30 A 100 μA 0.005 0.01 120 + 80 300 + 200 5
100 A 1 mA 0.005 0.01 120 + 80 300 + 200 5
High current loop 250 A 1 mA 0.01 0.01 120 + 80 300 + 200 7
500 A 1 mA 0.01 0.01 120 + 80 300 + 200 7
1000 A 10 mA 0.005 0.01 120 + 80 300 + 200 7
2000 A② 10 mA 0.005 0.01 120 + 80 300 + 200 7
Remarks: ②: 2100 A for option
  • Output Range of Current: 10 mA ~ 1100 A (2100 A);

  • Range Switching: Automatic or Manual

  • Resolution: 0.002 %*RG

  • Distortion: <0.5 % (except 1 kA/2 kA); <1 % @ 1 kA/2 kA range

  • Protection: Short-circuit protection, overload protection, overheating protection.

Frequency

Type Range Adjust fineness Accuracy (k = 2)
Frequency

40.000 Hz ~ 400.000 Hz

(1 kHz can be customized)

0.001 Hz 0.005%*RD

DC Voltage Output

Range Stability (%/min)

Accuracy (k = 2)

(ppm*RD + ppm*RG)

Max. Load

Current (mA)

0.02% 0.05% 0.02% 0.05%
200 mV 0.005 0.01 120 + 80 300 + 200 100
1 V 0.005 0.01 120 + 80 300 + 200 100
10 V 0.005 0.01 120 + 80 300 + 200 100
30 V 0.005 0.01 120 + 80 300 + 200 600
100 V 0.005 0.01 120 + 80 300 + 200 200
300 V 0.005 0.01 120 + 80 300 + 200 60
600 V 0.005 0.01 120 + 80 300 + 200 25
1000 V 0.005 0.01 120 + 80 300 + 200 20
  • Output Range of Voltage: 20 mV to 1100 V

  • Resolution: 0.002 % of range

  • Ripple Coefficient: <1 %

  • Protection: Short-circuit protection, overload protection, overheating protection.

DC Current Output

Model Range Resolution Stability (%/min)

Accuracy (k = 2)

(ppm*RD + ppm*RG)

Max. Load

Voltage (V)

0.02% 0.05% 0.02% 0.05%
Small current loop 100 mA 1 μA 0.005 0.01 150 + 50 300 + 100 10
300 mA 1 μA 0.005 0.01 150 + 50 300 + 100 10
1 A 10 μA 0.005 0.01 150 + 50 300 + 100 10
3 A 10 μA 0.005 0.01 150 + 50 300 + 100 10
10 A 100 μA 0.005 0.01 150 + 50 300 + 100 10
30 A 100 μA 0.005 0.01 150 + 50 300 + 100 5
100 A 1 mA 0.005 0.01 150 + 50 300 + 100 5
High current loop 250 A 1 mA 0.005 0.01 150 + 50 300 + 100 5
500 A 1 mA 0.005 0.01 150 + 50 300 + 100 5
1000 A 10 mA 0.005 0.01 150 + 50 300 + 100 5
2000 A② 10 mA 0.005 0.01 150 + 50 300 + 100 5
Remarks: ②: 2100 A for option
  • Output Range of Voltage: 20 mA ~ 1100 A (2100 A);

  • Resolution: 0.002 %*RG

  • Range Switching: Automatic or Manual

  • Distortion: <0.5 % (except 1 kA/2 kA); <1 % @ 1 kA/2 kA range

  • Protection: Short-circuit protection, overload protection, overheating protection.

Power Output (Option)

Type Range Accuracy (k = 2), (%*FS)③
0.02% 0.05%
DC Power Combination of DC voltage and current range. 0.05 0.1
Active Power |cosφ|≥0.5 Combination of AC voltage and current range. 0.05 0.1
0.5 0.05 0.1
Reactive Power |sinφ|≥0.5 0.05 0.1
Power Factor -1.0000…0.0000…+1.0000 0.05 0.1
0.05 0.1
Remark: ③: FS = Voltage range × Current range

Resistance

Range Resolution Allowable Current

Accuracy (k = 2)

(ppm*RD + ppm*RG)

100 Ω 1 mΩ 300 + 200 300 + 200
1 kΩ 10 mΩ 300 + 200 300 + 200
10 kΩ 100 mΩ 300 + 200 300 + 200
100 kΩ 1 Ω 300 + 200 300 + 200
1 MΩ 10 Ω 300 + 200 300 + 200
10 MΩ 100 Ω 600 + 400 600 + 400
100 MΩ 1 kΩ 10 nA ~ 50 nA 3000 + 2000
  • Output Range of Resistance: 10 Ω ~ 110 MΩ

  • Display: 6 digits

Send your message to this supplier
Send Now

TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter

Ask Latest Price
Name :
Fluke Multifunction Calibrator
Accuracy :
0.02% ; 0.05%
Origin :
China
Application :
Clamp ammeters
Features :
wide range, multi value and high precision
Model :
TD1050A
Contact Supplier
TD1050A Calibration Device Easy Traceability For AC DC Clamp Meter

Tunkia Co., Ltd.

Verified Supplier
2 Years
Since 1998
Business Type :
Manufacturer, Seller, Other
Main Products :
Employee Number :
300~500
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement