Type | Size | Weight KG/KM | OD Down mm | OD Up mm |
JT-RSUKU | 16.0*2C | 635 | 19.2 | 22.2 |
JT-RSUKU | 16.0*3C | 863 | 20.6 | 23.6 |
JT-RSUKU | 16.0*4C | 1111 | 23 | 26 |
JT-RSUKU | 16.0*5C | 1368 | 25.6 | 28.6 |
JT-RSUKU | 16.0*6C | 1632 | 28.4 | 31.4 |
JT-RSUKU | 25.0*2C | 940 | 23.6 | 26.6 |
JT-RSUKU | 25.0*3C | 1289 | 25.4 | 28.4 |
JT-RSUKU | 25.0*4C | 1668 | 28.3 | 31.3 |
JT-RSUKU | 25.0*5C | 2060 | 31.6 | 34.6 |
JT-RSUKU | 35*2C | 1233 | 26.9 | 29.9 |
JT-RSUKU | 35*3C | 1704 | 28.9 | 31.9 |
JT-RSUKU | 35*4C | 2213 | 32.3 | 35.3 |
JT-RSUKU | 35*5C | 2737 | 36 | 39 |
JT-RSUKU | 50.0*2C | 1701 | 31.8 | 34.8 |
JT-RSUKU | 50.0*3C | 2365 | 34.1 | 37.1 |
JT-RSUKU | 50.0*4C | 3078 | 38.1 | 41.1 |
JT-RSUKU | 50.0*5C | 3814 | 42.6 | 45.6 |
JT-RSUKU | 70.0*2C | 2272 | 36.4 | 39.4 |
JT-RSUKU | 70.0*3C | 3176 | 39.1 | 42.1 |
JT-RSUKU | 70.0*4C | 4145 | 43.7 | 46.7 |
JT-RSUKU | 70.0*5C | 5143 | 48.8 | 51.8 |
JT-RSUKU | 95.0*2C | 3030 | 42.2 | 45.2 |
JT-RSUKU | 95.0*3C | 4250 | 45.4 | 48.4 |
JT-RSUKU | 95.0*4C | 5556 | 50.7 | 53.7 |
JT-RSUKU | 95.0*5C | 6900 | 56.6 | 59.6 |
JT-RSUKU | 120.0*2C | 3710 | 46.4 | 49.4 |
JT-RSUKU | 120.0*3C | 5221 | 49.9 | 52.9 |
JT-RSUKU | 120.0*4C | 6835 | 55.8 | 58.8 |
JT-RSUKU | 120.0*5C | 8495 | 62.3 | 65.3 |
JT-RSUKU | 150.0*2C | 4611 | 51.9 | 54.9 |
JT-RSUKU | 150.0*3C | 6503 | 55.9 | 58.9 |
JT-RSUKU | 150.0*4C | 8520 | 62.5 | 65.5 |
JT-RSUKU | 150.0*5C | 10597 | 69.8 | 72.8 |
JT-RSUKU | 185.0*2C | 5547 | 56.6 | 59.6 |
JT-RSUKU | 185.0*3C | 7842 | 60.9 | 63.9 |
JT-RSUKU | 185.0*4C | 10285 | 68.1 | 71.1 |
JT-RSUKU | 185.0*5C | 12798 | 76.1 | 79.1 |
Flexible Cold Resistance, Weath Resistance, Reeling Crane Cable
Applications:
As connecting and control cable for lift or crane, it is also used for various kinds of electric installation in dry or wet in door as well as outdoor.
Properties:
The Butadiene-acrylonirile rubber outer sheath makes the cable resistant to ozone and UV radiation as well as oil, acid, flat and solvents.
Structure:
Conductor: Superfine copper strands acc. To VDE0295, class 5
Insulation: TPEE, TPE
Inner liner: Kevlar woven reinforcement
Outer sheath: PUR
Uted insulated cable rope among cores functions as tensile resistance
The outer sheath is flame retardant and self-extinguishing
(acc. To VDE0482, part 265-2-1 resp. EN50265-2-1 and IEC 60332-1). Color black.
Technical data:
Rated voltage: 450/750V, 0.6/1KV
Test Voltage: 2500V
Temperature range:
Fixed installation: -40degree to +90 degree/
Flexible application: -40degree to +90degree
Minimum bending radius: 10X outer diameter
Additonal sizes like 3x25+1x16, 3x120+1x70, 3x150+1x95 etc.