Specifications
Brand Name :
YOKG
Model Number :
SC40~65
Certification :
CE,TUV,CB
Place of Origin :
China
MOQ :
100PCS
Price :
Negotiable
Payment Terms :
L/C, D/P, T/T
Supply Ability :
100000pcs per Month
Delivery Time :
15days or Depends on ordering QTYS
Packaging Details :
Each unit be packed in one individual inner box
Rated heating current :
60A, 80A
Rated insulation voltage :
690V
Poles :
3
Standard :
IEC60947
Auxiliary contact :
NO/NC
Coil :
AC
Color :
Black
Pollution degree :
class 3
Description

110Vac Single Pole 4P Electrical Contactor Magnetic AC DP Definite Purpose Contactor

Application:

SC series AC contactor (hereinafter contactor) is suitable for using in the circuits up to the rated voltage 690V AC 50 HZ or 60 HZ , rated current up to 95A, for making, breaking, frequently starting & controlling the AC motor. Combined with the thermal relay, it becomes the electromagnetic starter for protecting the overload circuits.

This series contactor complies with GB 14048, IEC60947-4-1

Model and Implication:

110Vac 3 Poles AC Electric Contactor DP Definite Purpose Contactor

Main parameters and Technical Performance:

Type SC40 SC50 SC65
Rated heating current (A) 60 80 80
Rated insulation voltage (V) 690 690 690
Rated impact withstand voltage (KV) 6 6 6
Rated making capacity 10le 10le 10le
Rated breaking capacity 8le 8le 8le
Poles 3 3 3
Auxiliary contact NO+NC NO+NC NO+NC
Short-time withstand current(A) 10S 320 400 520
Rated working current(A) 380V AC-3 40 50 65
AC-4 18.5 24 28
660V AC-3 34 39 42
AC-4 9 12 14
AC-3 capacity of phase 3
squirrel-cage motor (AC-3) KW
220V 11 15 18.5
380V 18.5 22 30
660V 30 37 37
Operation frequency (times/h) Electrical life AC-3 600 600 600
AC-4 300 300 300
Mechanical life 3600 3600 3600
Electrical life (10000/times) AC-3 80 60 60
AC-4 15 15 15
Mechanical life (10000/times) 800 800 800
Equipped fuse type RT16-63 RT16-80 RT16-80
Rated control supply voltage Us(V) 50/60Hz 12~480 12~480 12~480
Operation range Pull-in (85%~110%)Us +40℃ (85%~110%)Us +40℃ (85%~110%)Us +40℃
Releasing (20%~75%)Us -5℃ (20%~75%)Us -5℃ (20%~75%)Us -5℃
Ac coil average power(VA) Start 200 200 200
Keeping 20 20 20
Power efficiency class class 3 class 3 class 3
Thermal loss(W) 6~10 6~10 6~10
Actuation time(ms) Close 20~25 20~25 20~25
Break 8~15 8~15 8~15
Main circuit wiring flexible wire without cold
pressing terminal (㎟)
1 stick 2.5~25 2.5~25 2.5~25
2 sticks 2.5~16 2.5~16 2.5~16
flexible wire with cold
pressing terminal (㎟)
1 stick 2.5~25 2.5~25 2.5~25
2 sticks 2.5~10 2.5~10 2.5~10
Hard wire (㎟) 1 stick 2.5~25 2.5~25 2.5~25
2 sticks 2.5~16 2.5~16 2.5~16
Fastening screw size M8 M8 M8
Tightening fastening torque (N.m) 3.5 3.5 3.5
Control loop wiring flexible wire without cold
pressing terminal (㎟)
1 stick 1~4 1~4 1~4
2 sticks 1~4 1~4 1~4
flexible wire with cold
pressing terminal (㎟)
1 stick 1~4 1~4 1~4
2 sticks 1~2.5 1~2.5 1~2.5
Hard wire (㎟) 1 stick 1~4 1~4 1~4
2 sticks 1~4 1~4 1~4
Fastening screw size M3.5 M3.5 M3.5
Tightening fastening torque (N.m) 0.8 0.8 0.8

Working and Installation Condition:

Ambient air temperature: -5℃--+40℃ and average not more than +35℃ within 24 hours;

Altitude: ≤ 2000m;

Air condition: when the highest temperature is +40℃, the air relative humidity is not up to 50%, but the higher humidity is allowed at lower temperature. Like, 90% humidity at 20℃. The condensate dew should be considered when at lower temperature;

Pollution degree: Class 3

Installation category:III

Protection degree: IP20

Installation condition: the gradient angle between installation side and vertical side should not be more than ±5℃

Impact and vibrattion: the contactor must be installed and operate under the circumstances of no obvious shaking, impact and vibration.

Structure characteristic:

Application: Auxiliary contacts block, time relay and current-limited contacts block, and thermal relay, then to be other derivative products;

Characteristic: small volume, light weight, less power loss, long life and safe and reliability etc;

Installation: The standard installing rail of 35mm (sc09~95) and the standard installing rail of 75mm(SC40~95), or screws

The contactor can be equipped with 1NO auxiliary contact or 1NC auxiliary contact(less than 32A), and 1NO auxiliary contact+1NC auxiliary contact(more than 40A). In addition, it can be equipped with F4 auxiliary contactor block (2blocks or 4blocks);


Installation dimension:

A max B max C max a b
77 129 116 40 100/110 6.5

110Vac 3 Poles AC Electric Contactor DP Definite Purpose Contactor

110Vac 3 Poles AC Electric Contactor DP Definite Purpose Contactor

110Vac 3 Poles AC Electric Contactor DP Definite Purpose Contactor

Send your message to this supplier
Send Now

110Vac 3 Poles AC Electric Contactor DP Definite Purpose Contactor

Ask Latest Price
Brand Name :
YOKG
Model Number :
SC40~65
Certification :
CE,TUV,CB
Place of Origin :
China
MOQ :
100PCS
Price :
Negotiable
Contact Supplier
110Vac 3 Poles AC Electric Contactor DP Definite Purpose Contactor
110Vac 3 Poles AC Electric Contactor DP Definite Purpose Contactor

YueQing ZEYI Electrical Co., Ltd.

Verified Supplier
4 Years
zhejiang, wenzhou
Since 1999
Business Type :
Manufacturer
Total Annual :
7.5 Million -8 Million
Employee Number :
50~70
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement