Efficient Flue Gas Waste Heat Recovery Gas - Vapor-Liquid Composite Heat Pipe Heat Exchanger
The boiler feed water and combustion air can also be heated separately. The structure can make full use of waste heat and achieve remarkable energy saving effect.
GFH series efficient flue gas waste heat recovery gas-liquid heat pipe heat exchanger technical specification
Model | Flue gas flow Nm³/h | Flue gas inlet temperat-ure ℃ | Flue gas outlet temperatur-e℃ | Liquid heating temperat-ure℃ | Air outlet tempera-ure℃ | Flue gas resistancePa | Smoke inlet and outlet dimensionsDNmm | Liquid inlet and outlet dimensions DNmm | Overall dimensions(mm) L×W×H | WeightKG |
GFH-1.0 | 1000 | 230-180 | 130 | 95-60 | 120 | 80 | 300 | 40 | 1200×700×1800 | 2120 |
GFH-2.0 | 2000 | 230-180 | 130 | 95-60 | 120 | 80 | 400 | 40 | 1200×800×2000 | 2920 |
GFH-4.0 | 4000 | 230-180 | 130 | 95-60 | 120 | 100 | 500 | 50 | 1400×800×2400 | 3610 |
GFH-6.0 | 6000 | 230-180 | 130 | 95-60 | 120 | 100 | 600 | 50 | 1600×1000×2400 | 4400 |
GFH-8.0 | 8000 | 230-180 | 130 | 95-60 | 120 | 120 | 800 | 65 | 1820×1000×2600 | 5790 |
GFH-10 | 10000 | 230-180 | 130 | 95-60 | 120 | 120 | 900 | 80 | 1820×1200×2800 | 7010 |
GFH-15 | 15000 | 230-180 | 130 | 95-60 | 120 | 200 | 1100 | 100 | 2200×1200×3100 | 9410 |
GFH-20 | 20000 | 230-180 | 130 | 95-60 | 120 | 230 | 1200 | 150 | 2500×1500×3100 | 11420 |
GFH-25 | 25000 | 230-180 | 130 | 95-60 | 120 | 260 | 1300 | 150 | 3000×1500×3100 | 13780 |
Note: The data listed are standard states, which can be adjusted reasonably according to the specific and special working conditions of users
1. Smoke entrance 2. Air outlet 3. Thermocouple
4. Cold air inlet 5. Smoke export 6. ash discharge valve
7. Safety valve 8. Water outlet 9. Water inlet