33/11Kv 5000Kva Three-Phase Oil Filled Power Transformer Supply Price
▶ using the corrugated tank sealing structure, enclosure, to prevent contact with air, water in contact with the transformer, reducing the degree of aging of the oil, to extend the service life of the transformer; Through the elastic deformation of corrugated to adjust the volume change of transformer oil heat bilges cold shrink.
▶ the product structure for the outdoor type, oil-free pillow,anti-fouling high level; ensure safe operation and reliability of the grid.
▶ the transformer has a pressure release safety devices, when a transformer failure pressure is too high. It can be safely released reliably through the pressure relief valve to prevent the expansion of the accident.
KVA | Voltage | VECTOR GROUP | LOSSES | No-Load Current | Weight(kg) | Overall dimension (mm) | |||||
H.V(KV) | L.V(KV) | No-Load Loss | Load Loss | Oil Weight | Total Weight | L | W | H | |||
20 | 6 6.3 10 10.5 11 13.2 | 380 400 415 433 | YynO Dyn11 Yzn11 | 90 | 530 | 2.3 | 55 | 230 | 720 | 440 | 855 |
30 | 100 | 600 | 2.1 | 75 | 305 | 750 | 500 | 990 | |||
50 | 130 | 870 | 2.0 | 80 | 405 | 800 | 480 | 1030 | |||
63 | 150 | 1040 | 1.9 | 95 | 455 | 830 | 615 | 1060 | |||
80 | 180 | 1250 | 1.9 | 105 | 510 | 840 | 580 | 1115 | |||
100 | 200 | 1500 | 1.8 | 120 | 530 | 890 | 645 | 1145 | |||
125 | 240 | 1800 | 1.7 | 130 | 670 | 910 | 600 | 1185 | |||
160 | 280 | 2200 | 1.6 | 140 | 810 | 910 | 700 | 1280 | |||
200 | 340 | 2600 | 1.5 | 160 | 890 | 1000 | 760 | 1240 | |||
250 | 400 | 3050 | 1.4 | 175 | 1020 | 1285 | 730 | 1290 | |||
315 | 480 | 3650 | 1.4 | 185 | 1170 | 1280 | 740 | 1385 | |||
400 | 570 | 4300 | 1.3 | 215 | 1410 | 1310 | 750 | 1432 | |||
500 | 680 | 5100 | 1.2 | 260 | 1645 | 1365 | 765 | 1510 | |||
630 | 810 | 6200 | 1.1 | 310 | 2070 | 1485 | 815 | 1615 | |||
800 | 980 | 7500 | 1.0 | 370 | 2445 | 1640 | 930 | 1590 | |||
1000 | 1150 | 10300 | 1.0 | 425 | 2800 | 1860 | 1120 | 1630 | |||
1250 | 1360 | 12000 | 0.9 | 480 | 3320 | 1860 | 1120 | 1830 | |||
1600 | 1640 | 14500 | 0.8 | 550 | 4175 | 1975 | 1175 | 1900 |
Typical test values and performances are performed in the painting lab on steel plates during the whole painting process in order to confirm the following:
• Minimum paint thickness film (ISO 2808): 70µm
• Specular gloss factor at 60 Deg (ISO 2813): 90 +/- 5%
• Falling weight test (ISO 6272): 1Kg/050cm
• Erichsen cupping test (ISO 1520): 08mm
• Scratch test (Adhesion ISO 2409): 0
• Bend Test (cylindrical mandrel ISO 1519): 3,0mm
• Salt spray (Fog) test (ISO 7253): Over 1000 Hours