LW26GS series Rotary Cam Switch 20A 2 Position with “OFF-ON”
General Features:
1. Wide range of function for switching, it has 20A,25A,32A,63A,125A,160A
2. Capability for switching of resistive, or inductive, or mixed loads.
3. The most economical way for switching electrical loads.
4. Made of the best materials with high mechanical, electrical and thermal resistance.
5. Double-break bimetallic contacts made of silver alloy and Copper.
6. Terminals with screws provided with cable clamp.
Description:
LW26GS series Pad-lock type switch are derivatives of LW26 series rotary switch.Insalled in equipment where it requires a pad-lock to lock the switch in certain position.For instance, to fix the switch in ON position,to prevent the unauthorized personnel from operation the switch.
LW26GS series Pad-lock type switch complies with the IEC 60947.3.
Advantage:
Technical parameters:
Description | LW26GS-20 | LW26GS-25 | LW26GS-32 | LW26GS-63 | LW26GS-125 | LW26GS-160 | |
Rated working voltage Ue | V | 440 | 440 | 440 | 440 | 440 | 440 |
Rated thermal current Ith | A | 20 | 25 | 32 | 63 | 125 | 160 |
Rated working current Ie | |||||||
AC-21A | A | 20 | 25 | 32 | 63 | 100 | 150 |
AC-22A | A | 20 | 25 | 32 | 63 | 100 | 150 |
AC-23A | A | 15 | 22 | 30 | 57 | 90 | 135 |
power | P | ||||||
AC-23A | KW | 7.5 | 11 | 15 | 30 | 45 | 75 |
Operation | |||||||
non-load | 8500 | 8500 | 8500 | 8500 | 8500 | 8500 | |
load | 1500 | 1500 | 1500 | 1500 | 1500 | 1500 | |
Total | 10000 | 10000 | 10000 | 10000 | 10000 | 10000 |
Description | Escutcheon plate | Dimensions(mm) | Installation(mm) | ||||||
A | C | L | H | E | F | D1 | D2 | ||
LW26GS-20/04-1 | M1 | 48 | 43 | 42 | 33 | 36 | 36 | Φ8.5 | Φ4.5 |
LW26GS-20/04-2 | M2 | 64 | 43 | 43 | 42 | 48 | 48 | Φ8.5 | Φ4.5 |
LW26GS-25/04-1 | M1 | 48 | 45.2 | 50 | 33 | 36 | 36 | Φ8.5 | Φ4.5 |
LW26GS-25/04-2 | M2 | 64 | 45.2 | 51 | 42 | 48 | 48 | Φ8.5 | Φ4.5 |
LW26GS-32/04-2 | M2 | 64 | 58 | 55 | 42 | 48 | 48 | Φ10 | Φ4.5 |
LW26GS-32/04-3 | M3 | 88 | 58 | 55 | 52 | 68 | 68 | Φ13 | Φ6 |
LW26GS-63/04-2 | M2 | 64 | 66 | 72.5 | 42 | 48 | 48 | Φ10 | Φ4.5 |
LW26GS-63/04-3 | M3 | 88 | 58 | 55 | 52 | 68 | 68 | Φ13 | Φ6 |
LW26GS-125/04-3 | M3 | 88 | 84 | 88 | 52 | 68 | 68 | Φ13 | Φ6 |
LW26GS-160/04-3 | M3 | 88 | 88 | 100 | 52 | 68 | 68 | Φ13 | Φ6 |
Normal working conditions:
1. Working temperature: -25°C~+40°C;the average temperature mustn’t be pass 35°C
2. Working height: ≤2,000m
3. Relative humidity: ≤50% with highest temperature +40°C,but allow higher humidity with low temperature less than 40°C.(eg. humidity 90%----teperature20°C)