7006-27F / 7006-28B Go No Go Gauge for E17 Lamp Cap Gague Conforms to IEC60061-3
Introduction:
E14 lamp cap and lampholder gauges are designed according to IEC60061-3:2004, they are applied to quality test of E14 cap. The structure and waveform are calculated by PC to reach high precision, and the appearance looks nice. The material is applied alloy steel. All the products equip with third-lab certificate authorized by CNAS.
Go Gauge for E14 caps on finished lamps (figure number: 7006-27F-1)
Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E14 caps on finished lamps.
Testing: when the cap on a finished lamp has been screwed into gauge as far as it will go, the centre contact shall be co-planar with, or project beyond surface X.
Not go gauge for E14 caps on finished lamps (figure number: 7006-28B-1)
Purpose: to check the minimum outside(major) diameter of the screw thread, dimension d, of E14 caps on finished lamps.
Testing: when the gauge is placed over the thread of the cap on a finished lamp, held cap uppermost, the centre contact shall not project beyond surface X.
Gauge for finished lamps fitted with E14 caps for testing protection against accidental contact (figure number: 7006-55-2)
Purpose: to check protection against accidental contact
Testing: The shape of the lamp with regard to protection against accidental contact is assumed to be correct if the test sample being pushed as far as possible into the gauge, plane W does not protrude beyond plane V.
Note: The application of this gauge is restricted to the lamps (candle lamps, round bulb lamps, domestic tubular lamps, pygmy lamps) when they are fitted with E14 caps, in according with sheet 7004-23.
Gauge for finished lamps fitted with E14 caps for testing contact making (7006-54-2)
Purpose: to check lamp dimension for contact making in IEC holders
Testing: the shape of the lamp with regard to the fit in the lampholder is assumed to be correct if the lamp can be pushed into the gauge till plane W reaches plane V or projects beyond it.
Go gauge for dimension “S1” of E14 caps on finished lamps (7006-27G-1)
Purpose: To check the dimensions S1 minimum and S1 maximum of E14 caps on finished lamps.
Testing: When the cap on a finished lamp has been pushed into the gauge as far as it will go, the plunger surface W shall be co-planar with or project beyond surface X but it shall not project beyond surface Y.
List of Lamp Cap Gauge
Figure Number | Description |
E27 Lamp Cap Gauge | |
7006-27B-1 | “Go” gauge for E27 caps on finished lamps |
7006-27C-1 | “Go” gauge for dimension “S1” of E27 caps on finished lamps |
7006-28A-1 | “Not Go” gauge for E27 caps on finished lamps |
7006-50-1 | Gauge for finished lamps fitted with E27 caps for testing contact making |
7006-51-2 | Gauge for caps on finished lamps for testing protection against accidental contact |
7006-51A-2 | Gauge for caps on finished lamps for testing protection against accidental contact during insertion |
E14 Lamp cap Gauge | |
7006-27F-1 | “Go” gauge for E14 caps on finished lamps |
7006-27G-1 | “Go” gauge for dimension “S1” of E14 caps on finished lamps |
7006-28B-1 | “Not Go” gauge for E14 caps on finished lamps |
7006-54-2 | Gauge for finished lamps fitted with E14 caps for testing contact making |
7006-55-2 | Gauge for finished lamps fitted with E14 caps for testing protection against accidental contact |
E12 Lamp Cap Gauge | |
7006-27H-1 | “Go” gauge for caps on finished lamps |
7006-27J-1 | Additional “Go” gauge for caps on finished lamps |
7006-28C-1 | “Not Go” gauge for caps on finished lamps |
7006-32-1 | gauge for finished lamps fitted with E12 caps for testing contact-making |
E26 lamp cap gauge | |
7006-27D-3 | “Go” gauge for caps |
7006-29L-4 | “Not Go” gauge for caps |
7006-29-3 | Gauge for testing contact-making of lamps fitted with caps |
E17 Lamp Cap Gauge | |
7006-27K-1 | “Go” gauge for caps on finished lamps |
7006-28F-1 | “Not Go’ gauge for caps on finished lamps |
7006-26D-1 | Gauge for testing contact-making of lamps fitted with caps |
E39 Lamp Cap gauge | |
7006-24A-1 | Gauge for finished lamps fitted with E39 caps for testing contact-making |
7006-24B-1 | “Go” gauge for caps on finished lamps |
7006-24C-1 | Gauge for testing contact-making of lamps fitted with caps |
E40 Lamp Cap gauge | |
7006-27-7 | “Go” gauge for caps on finished lamps |
7006-28D-1 | “Not Go” Gauge for caps on finished lamps |
7006-52-1 | Gauge for finished lamps fitted with E40 caps for testing contact making |
7006-53-1 | Gauge for finished lamps fitted with E40 caps for testing protection against accidental contact |
G13 Lamp Cap gauge | |
7006-44-4 | “Go” and “Not Go” gauge for unmounted Bi-Pin cap |
7006-45-4 | “Go” gauge for BI-Pin cap on finished lamps |
GU10 Lamp Cap gauge | |
7006-121-1 | Go and Not Go Gauge for Bases |
B22 & B22D Lamp Cap Gauge | |
7006-10-8 | Not Go Gauge for Caps on Finished Lamps |
7006-11-8 | Go gauge for Caps on Finished lamps BA9, B15, BA15 & B22 |
7006-4A-2 | Gauges for Testing the Insertion of Caps in lampholders B15d, B22d & BY22d |
7006-4B-1 | Gauges for Testing the Retention of B15d and B22d Caps in the Holder |
7006-3-1 | Acceptance Gauge for B22d Caps Intended for Automatic Wire Threading |
7006-17A-1 | Go Gauge for Cap on Finished Lamps BY22d |
G5 Lamp Cap Gauge | |
7006-46-3 | Go and Not Go gauge for Unmounted BI-PIN Cap |
7006-46A-3 | “Go” Gauge for BI-PIN Cap on Finished Lamps |
B22 Lamp Cap Gauge | |
7006-10-8 | Not Go Gauge for Caps on Finished Lamps |
7006-11-8 | Go gauge for Caps on Finished lamps BA9, B15, BA15 & B22 |
7006-4A-2 | Gauges for Testing the Insertion of Caps in lampholders B15d, B22d & BY22d |
7006-4B-1 | Gauges for Testing the Retention of B15d and B22d Caps in the Holder |
7006-3-1 | Acceptance Gauge for B22d Caps Intended for Automatic Wire Threading |
7006-17A-1 | Go Gauge for Cap on Finished Lamps BY22d |
B15 Lamp Cap Gauge | |
7006-4A-2 | B15 Lamp Cap and holder GO and Not Go Gauges |
7006-4B-1 | Gauges for testing the retention of B15d and B22d caps in the holder |
7006-10-8 | Not Go gauges for caps on finished lamps BA9, B15, B22 and BY22d |
7006-11-8 | Go gauges for caps on finished lamps BA9, B15, BA15 and B22 |
B15 Lampholder Gauge | |
7006-12C-2 | Supplementary “Go” Gauge for lampholders B15 |
7006-12D-2 | “Not Go”/Retention Gauge for Lampholders B15 |
7006-15B-1 | Gauges for Checking Contact Position and Contact Force in Bayonet Lampholders B15d |
Note: We accept customized gauges, please just send us the figure number on the inquiry, all the gagues can pass the third-lab calibration and get the ceritificates autorized by CNAS (IS017025).