IEC60061-3 Lamp Cap Gauge E27 Go Gauge No Go Gauge 7006-27B 7006-28A 7006-27C
Go Gauge for E27 Caps on Finished Lamps (7006-27B-1)
Purpose: to check the maximum dimensions of the screw thread and dimension T1 minimum of caps on finished lamps shown on sheet 7004-21.
Testing: When the cap on a finished lamp has been screwed into the gauge as far as it will go, the center contact shall be co-planar with or project beyond surface X.
Not Go Gauge for E27 Caps on Finished Lamps (7006-28A-1)
Purpose: to check the minimum outside(major) diameter of the screw thread, dimension “d” of E27 caps on finished lamps shown on sheet 7004-21
Testing: when the gauge is placed over the thread of the cap on a finished lamp, held cap uppermost, the center contact shall not project beyond surface X.
3) Go Gauge for Dimension S1 of E27 Caps on Finished Lamps (7006-27C-1)
Purpose: to check the dimension S1 minimum and S1 maximum of E27 caps on finished lamps shown on sheet 7004-21.
Testing: when the cap on a finished lamp has been pushed into the gauge as far as it will go, the plunger surface W shall be co-planar with or project beyond surface X but it shall not project beyond surface Y.
Figure Number | Description |
E27 Lamp Cap Gauge | |
7006-27B-1 | “Go” gauge for E27 caps on finished lamps |
7006-27C-1 | “Go” gauge for dimension “S1” of E27 caps on finished lamps |
7006-28A-1 | “Not Go” gauge for E27 caps on finished lamps |
7006-50-1 | Gauge for finished lamps fitted with E27 caps for testing contact making |
7006-51-2 | Gauge for caps on finished lamps for testing protection against accidental contact |
7006-51A-2 | Gauge for caps on finished lamps for testing protection against accidental contact during insertion |
E14 Lamp cap Gauge | |
7006-27F-1 | “Go” gauge for E14 caps on finished lamps |
7006-27G-1 | “Go” gauge for dimension “S1” of E14 caps on finished lamps |
7006-28B-1 | “Not Go” gauge for E14 caps on finished lamps |
7006-54-2 | Gauge for finished lamps fitted with E14 caps for testing contact making |
7006-55-2 | Gauge for finished lamps fitted with E14 caps for testing protection against accidental contact |
E12 Lamp Cap Gauge | |
7006-27H-1 | “Go” gauge for caps on finished lamps |
7006-27J-1 | Additional “Go” gauge for caps on finished lamps |
7006-28C-1 | “Not Go” gauge for caps on finished lamps |
7006-32-1 | gauge for finished lamps fitted with E12 caps for testing contact-making |
E26 lamp cap gauge | |
7006-27D-3 | “Go” gauge for caps |
7006-29L-4 | “Not Go” gauge for caps |
7006-29-3 | Gauge for testing contact-making of lamps fitted with caps |
E17 Lamp Cap Gauge | |
7006-27K-1 | “Go” gauge for caps on finished lamps |
7006-28F-1 | “Not Go’ gauge for caps on finished lamps |
7006-26D-1 | Gauge for testing contact-making of lamps fitted with caps |
E39 Lamp Cap gauge | |
7006-24A-1 | Gauge for finished lamps fitted with E39 caps for testing contact-making |
7006-24B-1 | “Go” gauge for caps on finished lamps |
7006-24C-1 | Gauge for testing contact-making of lamps fitted with caps |
E40 Lamp Cap gauge | |
7006-27-7 | “Go” gauge for caps on finished lamps |
7006-28D-1 | “Not Go” Gauge for caps on finished lamps |
7006-52-1 | Gauge for finished lamps fitted with E40 caps for testing contact making |
7006-53-1 | Gauge for finished lamps fitted with E40 caps for testing protection against accidental contact |
G13 Lamp Cap gauge | |
7006-44-4 | “Go” and “Not Go” gauge for unmounted Bi-Pin cap |
7006-45-4 | “Go” gauge for BI-Pin cap on finished lamps |
GU10 Lamp Cap gauge | |
7006-121-1 | Go and Not Go Gauge for Bases |
B22 & B22D Lamp Cap Gauge | |
7006-10-8 | Not Go Gauge for Caps on Finished Lamps |
7006-11-8 | Go gauge for Caps on Finished lamps BA9, B15, BA15 & B22 |
7006-4A-2 | Gauges for Testing the Insertion of Caps in lampholders B15d, B22d & BY22d |
7006-4B-1 | Gauges for Testing the Retention of B15d and B22d Caps in the Holder |
7006-3-1 | Acceptance Gauge for B22d Caps Intended for Automatic Wire Threading |
7006-17A-1 | Go Gauge for Cap on Finished Lamps BY22d |
G5 Lamp Cap Gauge | |
7006-46-3 | Go and Not Go gauge for Unmounted BI-PIN Cap |
7006-46A-3 | “Go” Gauge for BI-PIN Cap on Finished Lamps |
B22 Lamp Cap Gauge | |
7006-10-8 | Not Go Gauge for Caps on Finished Lamps |
7006-11-8 | Go gauge for Caps on Finished lamps BA9, B15, BA15 & B22 |
7006-4A-2 | Gauges for Testing the Insertion of Caps in lampholders B15d, B22d & BY22d |
7006-4B-1 | Gauges for Testing the Retention of B15d and B22d Caps in the Holder |
7006-3-1 | Acceptance Gauge for B22d Caps Intended for Automatic Wire Threading |
7006-17A-1 | Go Gauge for Cap on Finished Lamps BY22d |
B15 Lamp Cap Gauge | |
7006-4A-2 | B15 Lamp Cap and holder GO and Not Go Gauges |
7006-4B-1 | Gauges for testing the retention of B15d and B22d caps in the holder |
7006-10-8 | Not Go gauges for caps on finished lamps BA9, B15, B22 and BY22d |
7006-11-8 | Go gauges for caps on finished lamps BA9, B15, BA15 and B22 |
B15 Lampholder Gauge | |
7006-12C-2 |
Supplementary “Go” Gauge for lampholders B15 |
7006-12D-2 | “Not Go”/Retention Gauge for Lampholders B15 |
7006-15B-1 | Gauges for Checking Contact Position and Contact Force in Bayonet Lampholders B15d |
Note: Please send us the figure number on the inquiry.