IEC60529 IP Code Test Probes (Test Probe A, Test Probe B, Test Probe C, Test Probe D)
Test Probe A for IP1X Testing: Φ50 sphere with handle
Test Probe B for IP2X testing: jointed test finger
Test probe C for IP3X testing: Φ2.5 rod-length 100
Test Probe D for IP4X testing: Φ1.0 wire-length 100
Test Probe 1: 500g steel sphere
Test probe 2: 15g steel sphere
Test Probe A
Introduction:
Designed according to IEC61032 fig.1, and meet the requirements of IEC60529 regarding IP1X testing and IEC60065. This probe is intended to verify the protection of persons against access to hazardous parts. It is also used to verify the protection against access with the back of the hand.
Specification:
Diameter of test sphere: | 50mm | Diameter of baffle: | 50mm |
Thickness of baffle: | 4mm | Diameter of handle: | 10mm |
Length of handle: | 100mm | ||
Material: insulating material (handle and baffle), metal (test sphere) |
Test Probe B
Introduction:
Design according to IEC61032 figure 2, meet the requirements of UL507, UL1278 figure 8 and EN60529 figure 2. This probe is intended to verify the basic protection against access to hazardous parts. It is used to verify the protection against access with finger.
Specification:
Diameter of dactylogryposis: | 12mm | Length of dactylogryposis: | 80mm | |
Diameter of baffle: | 50mm | Length of baffle: | 100mm | |
Material: Insulating material (baffle and handle), metal(dactylogryposis) |
Test probe C
Introduction:
Designed according to IC61032 figure 3, meet the requirements of IEC60529-IP3, IEC60065,IEC60598 and etc. This rod is intended to verify the protection of persons against access to hazardous parts. It is used to verify protection against access with a tool.
Specification:
Length of test rod: | 100mm | Diameter of test rod: | 2.5mm |
Dimater of stop sphere: | 35mm | Diameter of handle: | 10mm |
Length of handle: | 100mm | ||
Material: Insulating material (handle, sphere), metal (test rod) |
Test Probe D
Introduction:
Designed according to IEC61032 figure 4, meet the requirements of IEC60529-IP3,IEC60065,IEC60598 and etc. This wire is intended to verify the protection of persons against access to hazardous parts. It is used to verify the protection against access with a wire.
Specification:
Length of test wire: | 100mm | Diameter of test wire: | 1mm |
Diameter of stop sphere: | 35mm | Diameter of handle: | 10mm |
Length of handle: | 100mm | ||
Material: Insulation material (handle, stop sphere), metal (test wire) |
Test Probe 1 (500g steel sphere)
Introduction:
Designed according to IEC61032 figure 5, meet the requirement of IEC60529-IP. The diameter of the sphere is 50mm+0.05, sphere is intended to verify the degree of protection of enclosures against ingress of solid foreign objects have a diameter of 50mm or greater.
Specification:
1). Diameter of sphere: 50mm+0.05
2). Weight of the sphere:500g
3). Material: steel
Test probe 2
Introduction:
Designed according to IEC61032 figure 6, meet the requirement of IEC60529-IP2. The diameter of sphere is 12.5+0.2, this sphere is intended to verify the degree of protection of enclosures against ingress of solid foreign objects having diameter of 12.5mm or greater.
Specification:
1). diameter of the sphere: 12.5mm (50.8mm, 63.5mm, 38.1mm choosable)
2). weight of the sphere: 15g
3). Material: steel sphere
4). Handle for optional