Specifications
Brand Name :
Delta
Model Number :
ETCR-5000
Certification :
ISO9001
Place of Origin :
China Mainland
MOQ :
1 set Power Quality Data Logger
Price :
USD1.0 / set Power Quality Data Logger
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :
100 sets Power Quality Data Logger / month
Delivery Time :
Within 10 days after the order is confirmed
Packaging Details :
Power Quality Data Logger is packed in one plywood case.
Description :
Three Phase Power Quality Analyzer and Power Quality Data Logger
Waveform Real-Time Display :
4 Channels Voltage/4 Channels Current
Current Measurement Range :
5A~2000A (Optional)
Power Supply :
AC100~240V,45Hz-55Hz
Voltage :
0-400V(Auto)
Current :
(Clamp Type) 5A/25A 100A/500A
Frequency Testing Range :
45~55Hz
Display Mode :
LCD Color Screen
Instrument Dimensions :
240mm*170mm*68 mm
Net Weight :
1.6kg (with Battery)
Gross Weight :
8kg (with Packaging)
Communication :
USB
Delivery Lead Time :
5 Days
Language :
English
Shipping Method :
by Courier
OEM Service :
Available
Description

Three Phase Power Quality Analyzer, Power Quality Data Logger

Introduction:
ETCR-5000 Three Phase Power Quality Analyzer, Power Quality Data Logger is specially designed for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, and phase electric parameters.

It applies to the electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institutions, and metrological department.
ETCR-5000 3 Phase Power Quality Analyzer Power Quality Data Logger is suitable for field tests of three phases, multi-functional and intelligent, concise man-machine operation.

Parameters:

Influence factor Test item Base condition Working condition
Environment temperature All parameters (23±2)°C -10°C~ 40°C
Relative humidity All parameters 40%~ 60% <80%
Phase-to-neutral voltage All parameters (100±1%)V 1.0V~ 1000V
Phase-to-phase voltage True RMS phase-to-phase voltage (200±1%)V 1.0V~ 2000V
Current True RMS current (5±1%)A 10mA~ 1000A
Network frequency All parameters 50Hz±0.1Hz 40Hz~ 70Hz
Phase shift Active power and active energy Cosφ=1 Cosφ: 0.2~ 1.0
Reactive power and reactive energy Sinφ=1 Sinφ: 0.2~ 1.0
Harmonic All parameters <0.1% 0.0%~ 100%
Voltage unbalance All parameters <10% 0.0%~ 100%
Working voltage of device All parameters DC9.8V±0.1V DC9.5V~ 10.5V
External electric field,
magnetic field
All parameters Should be avoided
Test position Measured related parameters of current Tested wire at the center of clamp.
Three Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data Logger
Power supply Rechargeable lithium-ion battery pack 9.6V, backup charger.
Battery indicator Battery symbol shows dump energy. When the voltage is too low, automatic shutdown after 1 minute.
Power consumption Current consumption of normal test 490 mA, continuous working for 8 hours.
Display mode LCD color screen, 640dots*480dots, 5.6 inches, display domain: 116mm*88mm.
Size of clamp 008 small sharp current clamp: 7.5mm*13mm;
040 circle current clamp: 35mm*40mm;
068 circle current clamp: 68mm*68mm;
Instrument dimensions L*W*H: 240mm*170mm*68 mm.
Number of channels 4U/4I.
Phase-to phase voltage 1.0V~2000V.
Phase-to-neutral voltage 1.0V~1000V.
Current 008 current clamp: 10mA~10.0A;
040 current clamp: 0.10A~100A;
068 current clamp: 1.0A~1000A;
Optional current transformer: instrument input current 1mA~500mA.
Frequency 40Hz~70Hz.
Parameters of electricity W, VA, Var, PF, DPF, cosφ, tanφ.
Energy parameters Wh, Varh, Vah.
Harmonic Order 0~50.
Total harmonic distortion Order 0~50, each phase.
Expert mode Yes.
Number of Transient records 150 sets.
Voltage flicker Yes.
Starting current mode Yes, 100 seconds.
3 phases unbalance Yes.
Record 300 days(simultaneous recording 20 parameters, record one point every 5 seconds).
Min/Max recorded value Measurement of maximum and minimum values over a period of time.
Alarm 40 different types of parameter selections, 12,800 sets alarm logs.
Peak Yes.
Phasor diagram display Automatically.
Capacity of snapshots 60.
Menu language English/Chinese.
Communication USB.
Automatic switching off When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.
In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.
Backlight function Yes, suitable for use at night and dark place.
Weight Host: 1.6kg (with battery).
008 small sharp current clamp: 170g*4;
040 circle current clamp: 190g*4;
068 circle current clamp: 510g*4;
Test wires and power adapter: 900g;
Total weight: about 10.5kg (with packaging).
Length of voltage test wire 3m.
Length of current sensor wire 2m.
Working temperature and humidity -10°C~40°C; below 80%Rh.
Storage environment -10°C~60°C; below 70%Rh.
Input impedance Input impedance of test voltage: 1MΩ.
Withstand voltage Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.
Insulation Between instrument wiring and shell ≥10MΩ.
Structure Double insulation, with insulation vibration-proof sheath.
Safely rules IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.
Packing Size 400*270*270(mm) (L*W*H)
Weight 8Kg
Three Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data Logger

Functions:
Waveform real-time display (4 channels voltage/4 channels current).
True RMS values of voltages and currents.
The DC components of voltages.
Peak current and voltage values.
Minimum and maximum half-cycle RMS current and voltage values.
Phasor diagram display.
Measurement of each harmonic up to order 50.
Bar charts show harmonic ratios of current and voltage of each phase.
Total harmonic distortion (THD).
Active, reactive, apparent power, by phase and cumulative.
Active, reactive, apparent energy, by phase and cumulative.
Transformer K factor.
Power factors (PF) and displacement factors (DPF or COSΦ).
Short-term voltage flicker (PST).
Three phase unbalance(current and voltage).


Three Phase Power Quality Analyzer, Power Quality Data LoggerThree Phase Power Quality Analyzer, Power Quality Data Logger

Send your message to this supplier
Send Now

Three Phase Power Quality Analyzer, Power Quality Data Logger

Ask Latest Price
Brand Name :
Delta
Model Number :
ETCR-5000
Certification :
ISO9001
Place of Origin :
China Mainland
MOQ :
1 set Power Quality Data Logger
Price :
USD1.0 / set Power Quality Data Logger
Contact Supplier
Three Phase Power Quality Analyzer, Power Quality Data Logger
Three Phase Power Quality Analyzer, Power Quality Data Logger
Three Phase Power Quality Analyzer, Power Quality Data Logger
Three Phase Power Quality Analyzer, Power Quality Data Logger
Three Phase Power Quality Analyzer, Power Quality Data Logger
Three Phase Power Quality Analyzer, Power Quality Data Logger

Delta Technology (Chongqing) Co., Ltd.

Verified Supplier
2 Years
chongqing, chongqing
Since 2012
Total Annual :
10000000-100000000
Employee Number :
100~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement