Specifications
Brand Name :
Lab
Model Number :
GC-7890
Certification :
ISO9001
Place of Origin :
China
MOQ :
1 set Gas Chromatograph in one order
Price :
Negotiable
Payment Terms :
Western Union, T/T, L/C
Supply Ability :
100 sets each month
Delivery Time :
7-15 days
Packaging Details :
Gas Chromatograph packed in veneer cases.
Description :
Transformer Oil 8 Kinds of Gases Testing Gas Chromatograph
Application :
Measure 8 Kinds of Gases in transformer oil
Measured gases :
H2, O2, N2, CO, CO2, CH4, C2H4, C2H6, C2H2
Temperature range :
Room temperature to 400℃
Features :
Powerful, good separation, high sensitivity, good reproducibility, easy operation, low failure rate, attractive appearance
Oven :
291*284*260mm, 21.5L
Dimension :
550 (W)*475 (height)* 460 (D) mm
Weight :
60kg
Description

GC7890 Transformer Oil 8 Kinds of Gases Testing Gas Chromatograph

Introduction:

  • The GC-7890 Transformer Oil Gas Chromatograph is a specific analysis instrument for transformer oil;

  • GC-7890 Transformer Oil Gas Chromatograph is a versatile designed for insulating oil dissolved gas content of the gas chromatograph analysis;

  • GC-7890 Transformer Oil Gas Chromatograph uses advanced double-column parallel, serial thermal conductivity detector, methane reformer, hydrochlorothiazide flame detector gas flow path can be completed in a single injection of insulating oil dissolved H2, O2, N2, CO, CO2, CH4, C2H4, C2H6, C2H2 composition analysis

  • GC-7890 Transformer Oil Gas Chromatograph is powerful, good separation, high sensitivity, good reproducibility, easy operation, low failure rate, attractive appearance, it can fully meet the need of transformer oil dissolved gases analysis;

Specifications:

1 Temperature range Room temperature +5℃~400℃
2 Temperature Accuracy ± 0.1℃
3 Settling Time ≤30min
4 Detection Limit

H2≤2uL/L; O2≤10uL/L; N2≤20uL/L; CO≤1uL/L;

CO2≤5uL/L; CH4,C2H4,C2H6,C2H2≤0.1uL/L;

5 Oven Size 291 (W) × 284 (height) × 260 (D) mm
6 Oven Volume 21.5L
7 Power AC ~ 220V ± 10%, 50 / 60HZ
8 Power ≤2000VA
9 Dimensions 550 (W)*475 (height)* 460 (D) mm
10 Weight ≤60kg
11 Ambient Temperature 5 ℃~35 ℃
12 Relative Humidity Less than 85%

Configuration:

  • Gas source:

  1. Nitrogen gas cylinder(40L gas cylinder + purity nitrogen + pressure relief valve)

  2. Hydrogen Generator

  3. Air Generator

  • GC-7890-DL transformer oil analysis specific gas chromatography: (A host, thermal conductivity detector, hydrochlorothiazide flame detectors, conversion furnace, three columns).

  • Dedicated transformer oil chromatography workstation

  • Automatic multi-functional oscillator

  • Standard gas(8L gas cylinder + gas + pressure relief valve)

  • Computers and printers

  • Toolkit(Pipes, fittings, spare parts, tools, syringes, needles sided, plastic caps,etc.

Features:

  • Large LCD display, keyboard input, display various parameters such as temperature, flow, etc., with real-time monitoring;
  • Automatic monitoring of the implementation of the heating zone. If heating zone is over temperature, heating power will be cut off automatically;
  • With stop gas protection function. When the carrier gas pressure is less than 0.1MPa, heating power will be cut off automatically;
  • With parameter storage function. The instrument will automatically run by the state of last shutdown, to achieve a true "one key to boot" function, or power meter will restore power automatically revert to the state before power on.
  • With a self-diagnostic function, the instrument operating parameters in real-time detection, when the system is abnormal, the computer system will automatically protect the instrument.
  • High re-producibility and pneumatic regulator system uses a unique process design, reduce the gas injection pressure fluctuation impact on the detector, thus maximizing the impact of reducing the impact of peak analysis to ensure the high accuracy of analysis.
  • The machine has changed the traditional three-box design, but using an advanced two-box design, the instrument look more clean and beautiful, and it also improve the safety of operation.
  • Carrier gas, hydrogen, air pressure gauge are adopted;
  • The main and key components are imported components to extend the machine's life and reduce maintenance costs.
  • Inlets, detectors and conversion furnace are modular design, they are very convenient for disassemble, the person without operating experience can also easily remove and replace the parts;
  • Large oven(291×284×260mm,21.5L) which is convenient to remove column;

GC7890 Transformer Oil 8 Kinds of Gases Testing Gas Chromatograph

GC7890 Transformer Oil 8 Kinds of Gases Testing Gas Chromatograph

Send your message to this supplier
Send Now

GC7890 Transformer Oil 8 Kinds of Gases Testing Gas Chromatograph

Ask Latest Price
Brand Name :
Lab
Model Number :
GC-7890
Certification :
ISO9001
Place of Origin :
China
MOQ :
1 set Gas Chromatograph in one order
Price :
Negotiable
Contact Supplier
GC7890 Transformer Oil 8 Kinds of Gases Testing Gas Chromatograph
GC7890 Transformer Oil 8 Kinds of Gases Testing Gas Chromatograph
GC7890 Transformer Oil 8 Kinds of Gases Testing Gas Chromatograph
GC7890 Transformer Oil 8 Kinds of Gases Testing Gas Chromatograph
GC7890 Transformer Oil 8 Kinds of Gases Testing Gas Chromatograph

Delta Technology (Chongqing) Co., Ltd.

Verified Supplier
2 Years
chongqing, chongqing
Since 2012
Total Annual :
10000000-100000000
Employee Number :
100~300
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement