IEC60695-2-2;
IEC60695-11-5
No. | Needle burner | Stainless steel, inner diameter of ¢ 0.5 ± 0.1mm, an outer diameter of not more than ¢ 0.9mm, length 35mm more needles, no air access |
1 | The burner angle | vertical (when adjusting and measuring the flame height) or inclined 45 ° test |
2 | Combustion gases | 95% butane gas or propane gas |
3 | Ignited bedding layer | white pine plank (thickness 10mm), surface covering 12 ~ 30g / m2 standard tissue paper layer is applied at lower flame from 200mm ± 5mm |
4 | Temperature range | 0--1000 ℃ |
5 | Flame temp. requirement | from 100 ± 2 ℃ ~ 700 ℃ ± 3 ℃, should be completed within 23.5 ± 1.0s |
6 | The flame height | 12mm ± 1mm |
7 | Burning time | 0s ~ 999.9s adjustable, generally set at 30s |
8 | Holding burning time | 0s ~ 999.9s, automatic recording, manual pause |
9 | Test Space | ≥0.5m3, black background, (can be customized cubic 0.75 m3 or 1 m3 according to customer requirements) |
10 | Temperature sensor | K-type insulation-sheathed thermocouple (Φ0.5mm) |
11 | Dimensions | L1120 * W520 * H1250mm, exhaust Φ100mm |
12 | Power supply | 220V / AC, 50H |