Three Phase IGBT Module AC Electric Motor Vector Frequency Inverter Speed Control VFD
Features
Item | Specification | ||
Standard functions | Maximum frequency | V/F control: 0~500Hz | |
Carrier frequency | 0.5kHz~16kHz | ||
The carrier frequency is automatically | |||
Input frequency | Digital setting: 0.01Hz | ||
Analog setting: maximum frequency x 0.025% | |||
Control mode | • Voltage/Frequency (V/F) control | ||
Basic functions | Speed range | 1:50 (VF) | |
Overload capacity | 60s for 150% of the rated current, 3s for 180% of the rated current | ||
Torque boost | •Fixed boost | ||
• Customized boost 0.1%–30.0% | |||
V/F curve | • Straight-line V/F curve | ||
• Multi-point V/F curve | |||
•N-power V/F curve (1.2-power, 1.4-power, | |||
V/F separation | Two types: complete separation; half separation | ||
Acceleration deceleration curve | •Straight-line ramp | ||
• S-curve ramp | |||
Four groups of acceleration/deceleration time | |||
DC braking. | DC braking frequency: 0.00Hz~maximum frequency | ||
Braking time: 0.0s~36.0s | |||
Braking action current value: 0.0%–100.0% | |||
JOG control | JOG frequency range: 0.00–50.00 Hz | ||
JOG acceleration/deceleration time: 0.0–6500.0s | |||
Simple PLC and | It implements up to 16 speeds via the simple PLC function or combination of DI terminal states. | ||
multi-speed operation | |||
Onboard PID | It realizes process-controlled closed loop control system easily. | ||
Automatic voltage | It can keep constant output voltage automatically | ||
regulation (AVR) | |||
Overvoltage | The current and voltage are limited automatically | ||
Quick current limiting | Maximize overcurrent failure and | ||
Torque limit and control | It can limit the torque automatically and prevent frequent | ||
Bus support | Support field bus: Modbus, to realize system integration | ||
Individualized functions | Electrify peripheral | to electrify and to do the security detection of peripheral equipment | |
Sharing DC bus fuction | to realize several frequency inverters sharing the DC bus | ||
Timing control | Time range: 0.0–65535.0 minutes | ||
Spinning Oscillating | multi-triangular frequency control function | ||
Operation | Command source | Operation panel, control terminal and serial | |
Switch in various methods | |||
Frequency source | Various frequency sources: digital reference, analog voltage | ||
Auxiliary frequency source | 10 kinds of auxiliary frequency source. | ||
5 digital input terminals, compatible active PNP or NPN input mode | |||
2 analog input terminals, among which one only supports voltage | |||
Output terminal | 1 digital output terminal | ||
1 relay output terminal | |||
1 analog output terminal, supporting current outpout | |||
Display and | LED display | Display the parameter | |
Key lock and | Realize partial or all key lock and define the action range | ||
Protection function | Short circuit test of electrified motor, input/output default | ||
Options | IO expansion card, differential input PG card, | ||
Environment | Service site | Indoor, free from direct sunshine, no dust, corrosive gas, | |
Altitude | Less than 1,000m | ||
Ambient temperature | -10℃~ +40℃ (Please use the equipment by | ||
Humidity | Less than 95%RH, no water condensation | ||
Vibration | Less than 5.9m/s2(0.6g) | ||
Storage temperature | -20℃~ +60℃ |