Pump Control Three Phase Soft Start Controller , 50 / 60Hz 55KW Soft Starter
Intelligent motor soft starter, the use of intelligent digital control; With the single chip processor as the intelligence center, thyristor module for actuators for full automatic control motor. It applies various squirrel-cage asynchronous motor control of load, the motor can smooth starting under any working conditions, protect the drag system, reduce the starting current impact on power grid, ensure reliable motor starting. Smoothly soft stopping function can effectively solve the inertial system surge problem, eliminate the drag system of inertial impact, that is traditional equipment cannot be achieved. Intelligent digital motor soft start equipment system with the complete protection function, extend the service life of the system, reduce the cost of system cost, improve the reliability of system and compatible with all the functions of starting equipment; It is a new ideal alternative for traditional star triangle starter and self-coupling decompression starter.
Features
1.The computer simulation design, SMT production process, Good EMC performance.
2.Perfect protection function: No voltage, less voltage, over voltage, over heating, starting time too long,Input phase lost, output phase lost, 3 phase unbalance, starting over current, running overload, load short circuit.
3.Fault self-diagnosis(short circuit, over voltage, less voltage, one phase grounded, motor overload, one phase lost, motor blocked, and intelligent software can inspect drag system working state).
4.Combination of modular design, according to the fault display content, quick troubleshooting.
5.Independently software copyright.
6.Motor starting and protection proprietary technology.
7.Unique way to detect debug equipment and process.
8.Reliable performances lay the foundation of qualified service and quality.
9.Provide perfect system solution.
10.The timely and thoughtful Consulting Services.
11.Constantly improve the product performance according to user's opinion.
Conditions Of Usage
Item | Description |
Power supply | AC380V±15% |
Power frequency | 50/60Hz |
Adaptive Motor | Squirrel-cage three-phase asynchronous motor |
Starting times | It is recommended not to exceed 20 times per hour |
Control mode | 1) Operation panel control; 4) External control+ COM control ; 7) COM control ; |
Start Mode | 1) Current-limiting start; 4) Torque control +voltage ramp to start; |
Stop Mode | 1) Soft stop; 2) Free stop; |
Protective Function | 1) Open loop protection for external instantaneous stop terminals; 2) Over-heat protection for soft starter; 4) Input open phase protection; 7) Starting over current protection; 10) Overvoltage protection for power voltage; 13) Auto restart or incorrect wiring protection; |
Protection Class | IP00,IP20 |
Cooling Pattern | Natural wind cooling |
Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. |
Environment Condition | Below 2000M. Rise the rate power when the altitude is more than 2000M. Ambient Temperature -25+45°C Ambient Humidity 95%(20°C±5°C) Vibration<0.5G |
Dimension
Maintenance
1. Dust: If too much dust, it will reduce the insulation level of the soft starter, even causes the soft starter does not work.
Brush the dust with clean and dry brush.
Remove dust with compressed air machine.
2. Condensation: If condensation, it will reduce the insulation level of soft starter, even causes the soft starter does not work.
(1) Blow it with a hair dryer or electric stove.
(2) Bring it to power distribution room for dehumidification.
3. Regularly check components' intact. Whether it can work properly.
4. Check soft starter' cooling channel, ensure they are not clogged by dirt and dust.
Before maintenance checking, it has to cut off all power in the line side of soft starter.