GTJ-U910 non-metal ultrasonic detector
Overview of use:
Structural concrete compressive strength, crack depth, crack width and defect detection; ultrasonic transmission method to detect the integrity of foundation pile and continuous wall; set pile, ultrasonic rebound comprehensive method strength measurement, lack of measurement, crack sounding and width measurement In one. Geological exploration, rock integrity, weathering evaluation test; mechanical properties of non-metallic materials such as rock mass and concrete.
Features:
With perfect functions, stable performance and high cost performance, it is the best choice for users with diverse needs such as teaching and research.
Semi-transparent, high-brightness, TFT color LCD screen, clearer in the sun;
Wifi connection slit width function;
Double injection molding, waterproof, anti-drop design, protection grade IP65;
Applicable standards:
Ultrasonic Testing of Concrete Defects - CECS 21:000
Technical Specification for Ultrasonic Rebound Comprehensive Method for Testing Concrete Strength-CECS 02:2005
"Code for Testing Concrete Strength of Railway Engineering Structures"-TB 10426-2004
Technical Regulations for Concrete Structure Detection of Water Transportation Engineering-JTS 239-2015
"Technical Regulations for Strength Testing of High Strength Concrete"-JGJ/T294-2013
Technical Specification for Rebound Method and Ultrasonic Rebound Comprehensive Method for Testing Pumped Concrete Strength-DBJ/T01-78-2003
Technical Regulations for Testing Concrete Compressive Strength-DG/TJ08-2020-2007
Technical Specification for Ultrasonic Rebound Comprehensive Method for Testing Concrete Strength-DB37/T 2361-2013
Technical Specification for Ultrasonic Rebound Comprehensive Method for Testing Concrete Strength-DBJ53/T-53-2013
Technical Specification for Ultrasonic Rebound Comprehensive Method for Testing Concrete Strength of Highway Engineering-DB51/T1996-2015
"Technical Specifications for Building Pile Testing"-JGJ 106-2014
"Technical Regulations for Dynamic Testing of Piles in Highway Engineering"-JTG/T F81-01-2004
Technical Regulations for Testing Pile Foundations in Railway Engineering-TB 10218-2008
Code for Building Foundation Testing - DBJ 15-60-2008
"Shenzhen Building Foundation Pile Inspection Procedures"-SJG09-2015
"Technical Specifications for Building Pile Testing"-DGJ08-218-2003
Technical Parameters:
Model | GTJ-U910 Non-Metal Ultrasonic Detector |
Main control unit | Built-in A8 industrial control board |
Display | 10.1 inch, high brightness, TFT color LCD capacitive screen |
Mode of operation | Touch screen |
Storage method | Built-in electronic hard disk (≥48B) + large capacity U disk |
Acquisition mode | Single channel manual point by point acquisition |
Number of channels | 1 transmit +1 receive |
Trigger mode | signal trigger |
Sampling period (μs) | 0.05~409.6 multiple options |
Sound time accuracy (μs) | 0.05 |
Sound time range (μs) | ±1677700 |
Seam width function | Measuring range: 0~10mm; measuring accuracy: 0.01mm; Connection method: wifi |
Dynamic range (dB) | 146 |
Bandwidth (kHz) | 1~500 |
Receive sensitivity (μV) | ≤10 |
Gain accuracy (dB) | 0.5 |
Transmitting voltage (V) | 65, 250, 500, 1000 four adjustable |
Communication interface | USB, Bluetooth, wifi |
Working time (h) | ≥8 |
Power supply mode | Built-in lithium battery External 220V ~ 16V AC / DC |
Working environment | Temperature (°C)-10°C~+40°C Humidity (RH) < 90% |
Host size (mm) | 300 × 200 × 55 |