Single arrangement moving walk / Indoor / Outdoor 0 ° / 10 ° / 11 ° / 12 °
· Moving walk has extremely strong conveying capacity. It can satisfy the traffic requirements of modern people in various aspects. It is applicable for the airport, shopping center, hotel, recreation center etc.
· Its unique and innovative design has minimum requirements to the space. Its firm structure is strong enough for any kind of load. At the same time of converying large-size shopping plaza and busy airport; bus station, it saves every piece of precious space. It fully considers the requirements of modern city traffic.
· 0-12° angle of inclination can be freely choice according to different use and enviroment in the building.
SN-XDRM Single arrangement moving walk (indoor)
Power meter(Pedal width 1000mm speed 0.5m/s)
5.5KW | 8KW | 11KW |
1.2m≤H≤3.0m | 3.0m<H≤4.5m | 4.5m<H≤6.0m |
15KW | / | / |
6.0m<H≤7.0m | / | / |
Table of Rules of Extension Interior Moving walk’s Upper Part
Power | |||||
Step width | <15KW | 15KW | 2x11KW | 2x15KW | |
NO VVVF | 800 | 0 | 0 | 500 | / |
1000 | 0 | 0 | 500 | 800 | |
VVVF | 800 | 0 | 200 | 500 | / |
1000 | 0 | 0 | 500 | 800 |
Specification(Single-row room1500 type)
Model | SN-XDRM-800 | |
SN-XDRM-1000 | ||
Speed | 0.5m/s | |
Height | H≤7000mm | |
Angle | 12° | |
Support forceR1 | KN | |
Support forceR2 | KN | |
Support forceR3 | KN | |
Support forceR4 | KN | |
Weight | KN | |
Power supply | Power | Three-phase AC 380V 50Hz |
Illumination | Single phase AC 220V 50Hz |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.