Specifications
Brand Name :
BT Lab
Model Number :
Cat.No E2018Bo
Certification :
CE, ISO9001:2005, MSDS
Place of Origin :
Shanghai, China
MOQ :
1 kit
Price :
Negotiation
Payment Terms :
Western Union, T/T
Supply Ability :
In Stock
Delivery Time :
1-3 business days, bulk order within one week
Packaging Details :
Wrapped with ice pack and styrofoam package
Target Protein :
Fetuin A
Sample :
serum,plasma,urine,tissue,cell culture supernatant
Uniprot No. :
P12763
Discount :
Available
Customized :
Acceptable
Cat.No :
E2018Bo
Description

Bovine Fetuin A ELISA Kit with High Spesificity and Sensitivity

Cat.No E2018Bo

Standard Curve Range: 5mg/L - 1800mg/L

Sensitivity: 2.54mg/L

Size: 96 wells

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

* This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.

Intended Use

This sandwich kit is for the accurate quantitative detection of Bovine Fetuin A (also known as FETU-A) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.

Assay Principle

This kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with Bovine FETU-A antibody. FETU-A present in the sample is added and binds to antibodies coated on the wells. And then biotinylated Bovine FETU-A Antibody is added and binds to FETU-A in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated FETU-A antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of Bovine FETU-A. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.

960mg/L Standard No.5 120μl Original Standard + 120μl Standard Diluent
480mg/L Standard No.4 120μl Standard No.5 + 120μl Standard Diluent
240mg/L Standard No.3 120μl Standard No.4 + 120μl Standard Diluent
120mg/L Standard No.2 120μl Standard No.3 + 120μl Standard Diluent
60mg/L Standard No.1 120μl Standard No.2 + 120μl Standard Diluent

Standard Concentration Standard No.5 Standard No.4 Standard No.3 Standard No.2 Standard No.1
1920mg/L 960mg/L 480mg/L 240mg/L 120mg/L 60mg/L

Wash Buffer Dilute 20ml of Wash Buffer Concentrate 30x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.

Assay Procedure

1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.

2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.

3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution contains biotinylated antibody.

4. Add 40μl sample to sample wells and then add 10μl anti-FETU-A antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells (Not blank control well). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.

5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.

6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.

7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.

8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.

References

[1] "Site-specific glycoprofiling of N-linked glycopeptides using MALDI-TOF MS: strong correlation betweensignal strength and glycoform quantities."Thaysen-Andersen M., Mysling S., Hojrup P.Anal. Chem. 81:3933-3943(2009)

Send your message to this supplier
Send Now

2.54mg/L Sensitivity Fetuin A Bovine ELISA Kits for Lab Research Use

Ask Latest Price
Brand Name :
BT Lab
Model Number :
Cat.No E2018Bo
Certification :
CE, ISO9001:2005, MSDS
Place of Origin :
Shanghai, China
MOQ :
1 kit
Price :
Negotiation
Contact Supplier
2.54mg/L Sensitivity Fetuin A Bovine ELISA Kits for Lab Research Use

Shanghai Korain Biotech Co., Ltd

Active Member
7 Years
shanghai, shanghai
Since 2010
Business Type :
Manufacturer, Distributor/Wholesaler, Exporter, Seller
Certification Level :
Active Member
Contact Supplier
Submit Requirement